PME SETUP FILE 32Bit
Created: 2011-10-26 12:47:46
Device ID (Address) 110
S/N: 150120105
Hardware version: 2.06
Firmware version: 2.06
CAN-Baud rate: 0
Keaboard active: No
Sensor type: Full bridge
Shunt: ---
Supply voltage 5 V
Input range 3 mV/V
Filter characteristics Bessel
Filter frequency 1 Hz
Zero value 0 kg
.49147 mV/V
Nominal value 10 kg
2.9375 mV/V
1st calibration pt.: 0 kg
.49147 mV/V
2nd calibration pt.: 1 kg
.78522 mV/V
Display precision 0.000
Step 1
Zero balance: 0 kg
Zero ref. 0 kg
Tare value: 0 kg
Limit values 1
Signal source Gross
Limit value monitoring ON
Switching direction Level overflow
Switch level: 10 kg
Switch hysteresis: .5 kg
Switching delay positive: 0 ms
Switching delay negative: 0 ms
Limit values 2
Signal source Gross
Limit value monitoring ON
Switching direction Level overflow
Switch level: 10 kg
Switch hysteresis: .5 kg
Switching delay positive: 0 ms
Switching delay negative: 0 ms
Limit values 3
Signal source Gross
Limit value monitoring ON
Switching direction Level underflow
Switch level: -10 kg
Switch hysteresis: .5 kg
Switching delay positive: 0 ms
Switching delay negative: 0 ms
Limit values 4
Signal source Gross
Limit value monitoring ON
Switching direction Level underflow
Switch level: -10 kg
Switch hysteresis: .5 kg
Switching delay positive: 0 ms
Switching delay negative: 0 ms
Peak value :
Input signal MIN: Gross
Input signal MAX: Gross
Envelope discharge 0 kg/ s
Digital outputs:
Output0: Error neg. logic
Output1: Inactive pos. logic
Output2: Inactive pos. logic
Output3: Inactive pos. logic
Digital inputs:
Remote control on
Tare: Input 2
Peak value Max / MomValue: Inactive
Peak value Min / MomValue: Inactive
Hold peak value Max: Inactive
Hold Peak value Min: Inactive
Set zero Input 1
Set Parameter Set Bit 1: Input 3
Set Parameter Set Bit 2: Input 4
Analog out:
Source: Gross
Zero value: 0 kg
0 mA (range: +/- 20 mA)
End value: 1 kg
20 mA (range: +/- 20 mA)
Motion control:
status Inactive
Delay 500 ms
Amplitude 1 kg
PDO message:
PDO value 0 by User
Format 4 Byte Integer
Intervall 0 ms
Lock dialogs:
Deactivate password input locked
Dialog unlocked
Parameter set unlocked
Display unlocked
Transducer unlocked
Signal conditioning unlocked
Analog out unlocked
Limit values unlocked
Peak values unlocked
In-/Output unlocked
CAN-Bus unlocked
Additional functions unlocked
Signal conditioning unlocked