PME SETUP FILE 32Bit
|
||
|
|
||
|
Created: 2011-10-26 12:47:46
|
||
|
|
||
|
Device ID (Address) 110
|
||
|
S/N: 150120105
|
||
|
Hardware version: 2.06
|
||
|
Firmware version: 2.06
|
||
|
CAN-Baud rate: 0
|
||
|
Keaboard active: No
|
||
|
Sensor type: Full bridge
|
||
|
Shunt: ---
|
||
|
Supply voltage 5 V
|
||
|
Input range 3 mV/V
|
||
|
Filter characteristics Bessel
|
||
|
Filter frequency 1 Hz
|
||
|
Zero value 0 kg
|
||
|
.49147 mV/V
|
||
|
Nominal value 10 kg
|
||
|
2.9375 mV/V
|
||
|
1st calibration pt.: 0 kg
|
||
|
.49147 mV/V
|
||
|
2nd calibration pt.: 1 kg
|
||
|
.78522 mV/V
|
||
|
Display precision 0.000
|
||
|
Step 1
|
||
|
Zero balance: 0 kg
|
||
|
Zero ref. 0 kg
|
||
|
Tare value: 0 kg
|
||
|
|
||
|
Limit values 1
|
||
|
Signal source Gross
|
||
|
Limit value monitoring ON
|
||
|
Switching direction Level overflow
|
||
|
Switch level: 10 kg
|
||
|
Switch hysteresis: .5 kg
|
||
|
Switching delay positive: 0 ms
|
||
|
Switching delay negative: 0 ms
|
||
|
|
||
|
Limit values 2
|
||
|
Signal source Gross
|
||
|
Limit value monitoring ON
|
||
|
Switching direction Level overflow
|
||
|
Switch level: 10 kg
|
||
|
Switch hysteresis: .5 kg
|
||
|
Switching delay positive: 0 ms
|
||
|
Switching delay negative: 0 ms
|
||
|
|
||
|
Limit values 3
|
||
|
Signal source Gross
|
||
|
Limit value monitoring ON
|
||
|
Switching direction Level underflow
|
||
|
Switch level: -10 kg
|
||
|
Switch hysteresis: .5 kg
|
||
|
Switching delay positive: 0 ms
|
||
|
Switching delay negative: 0 ms
|
||
|
|
||
|
Limit values 4
|
||
|
Signal source Gross
|
||
|
Limit value monitoring ON
|
||
|
Switching direction Level underflow
|
||
|
Switch level: -10 kg
|
||
|
Switch hysteresis: .5 kg
|
||
|
Switching delay positive: 0 ms
|
||
|
Switching delay negative: 0 ms
|
||
|
|
||
|
Peak value :
|
||
|
Input signal MIN: Gross
|
||
|
Input signal MAX: Gross
|
||
|
Envelope discharge 0 kg/ s
|
||
|
|
||
|
Digital outputs:
|
||
|
Output0: Error neg. logic
|
||
|
Output1: Inactive pos. logic
|
||
|
Output2: Inactive pos. logic
|
||
|
Output3: Inactive pos. logic
|
||
|
|
||
|
Digital inputs:
|
||
|
Remote control on
|
||
|
Tare: Input 2
|
||
|
Peak value Max / MomValue: Inactive
|
||
|
Peak value Min / MomValue: Inactive
|
||
|
Hold peak value Max: Inactive
|
||
|
Hold Peak value Min: Inactive
|
||
|
Set zero Input 1
|
||
|
Set Parameter Set Bit 1: Input 3
|
||
|
Set Parameter Set Bit 2: Input 4
|
||
|
|
||
|
Analog out:
|
||
|
Source: Gross
|
||
|
Zero value: 0 kg
|
||
|
0 mA (range: +/- 20 mA)
|
||
|
End value: 1 kg
|
||
|
20 mA (range: +/- 20 mA)
|
||
|
|
||
|
Motion control:
|
||
|
status Inactive
|
||
|
Delay 500 ms
|
||
|
Amplitude 1 kg
|
||
|
|
||
|
PDO message:
|
||
|
PDO value 0 by User
|
||
|
Format 4 Byte Integer
|
||
|
Intervall 0 ms
|
||
|
|
||
|
|
||
|
Lock dialogs:
|
||
|
Deactivate password input locked
|
||
|
Dialog unlocked
|
||
|
Parameter set unlocked
|
||
|
Display unlocked
|
||
|
Transducer unlocked
|
||
|
Signal conditioning unlocked
|
||
|
Analog out unlocked
|
||
|
Limit values unlocked
|
||
|
Peak values unlocked
|
||
|
In-/Output unlocked
|
||
|
CAN-Bus unlocked
|
||
|
Additional functions unlocked
|
||
|
Signal conditioning unlocked
|
||
|
|