You cannot select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
486 lines
12 KiB
Plaintext
486 lines
12 KiB
Plaintext
2 years ago
|
$ EDS-File for Beckhoff Fieldbus-Box
|
||
|
$ Created by: Stefan Dillmann 09/30/2003
|
||
|
$
|
||
|
$
|
||
|
$
|
||
|
$ Default IO-Mapping Info, see end of EDS-File
|
||
|
$
|
||
|
$
|
||
|
$
|
||
|
$ For additional information please contact:
|
||
|
$
|
||
|
$ Headquarters:
|
||
|
$ Beckhoff Automation GmbH, Eiserstr. 5, D-33415 Verl, Germany
|
||
|
$ phone +49 5246 963-0, fax +49 5246 963-198
|
||
|
$ support@beckhoff.com,
|
||
|
$ Support Hotline: +49 5246 963-157
|
||
|
$ web: www.beckhoff.com
|
||
|
$
|
||
|
$ North America
|
||
|
$ USA, Canada, Mexico
|
||
|
$ Beckhoff Automation LLC, 12150 Nicollet Avenue South, Minneapolis ,MN 55337, USA
|
||
|
$ phone +1 952 8900000, fax +1 952 8902888,
|
||
|
$ support.usa@beckhoff.com
|
||
|
$ Support Hotline: +1 (952) 890 0000
|
||
|
$ web: www.beckhoff.com
|
||
|
$
|
||
|
$
|
||
|
$
|
||
|
$ Default IO-Mapping Info, see end of EDS-File
|
||
|
$
|
||
|
$
|
||
|
$
|
||
|
$ EDS-File History:
|
||
|
$ Revision 1.1: Initial Release
|
||
|
$ Revision 1.2: Update Company Information
|
||
|
|
||
|
|
||
|
[File]
|
||
|
DescText = "EDS File for Beckhoff Fieldbus-Box";
|
||
|
CreateDate = 09-30-2003;
|
||
|
CreateTime = 10:00:00;
|
||
|
ModDate = 02-06-2006;
|
||
|
ModTime = 10:00:00;
|
||
|
Revision = 1.2;
|
||
|
|
||
|
|
||
|
[Device]
|
||
|
VendCode = 108;
|
||
|
VendName = "Beckhoff Automation";
|
||
|
ProdType = 0;
|
||
|
ProdTypeStr = "Generic Device";
|
||
|
ProdCode = 2512;
|
||
|
MajRev = 1;
|
||
|
MinRev = 10;
|
||
|
ProdName = "IP2512-B520 V01.10";
|
||
|
Catalog = "IP2512-B520";
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
[IO_Info]
|
||
|
Default = 0X0001; $ Poll Connection is default
|
||
|
PollInfo = 0X000D, 1, 1;
|
||
|
COSInfo = 0X0005, 1, 1;
|
||
|
CyclicInfo = 0X0009, 1, 1;
|
||
|
|
||
|
|
||
|
$ Input Connections
|
||
|
$ Assemblies
|
||
|
|
||
|
Input1=
|
||
|
7, $ 7 bytes length
|
||
|
0, $ all bits are significant
|
||
|
0x000D, $ Poll, BitStrobe, Change of State and Cyclic
|
||
|
"Status + DataIn", $ Name
|
||
|
6, "20 04 24 AD 30 03", $ Assembly Inst. 173
|
||
|
"Mapping, see EDS-File or Manual"; $ Help String
|
||
|
|
||
|
$ Mapping Info:
|
||
|
$ Channel 1: Byte0 : Status Register Communication Channnel 1
|
||
|
$ Byte1 : DataIn Low Byte Channel 1
|
||
|
$ Byte2 : DataIn High Byte Channel 1
|
||
|
$ Channel 2: Byte3 : Status Register Communication Channnel 2
|
||
|
$ Byte4 : DataIn Low Byte Channel 2
|
||
|
$ Byte5 : DataIn High Byte Channel 2
|
||
|
$ Byte6:(vendor specific status byte)
|
||
|
$ bit0 = Internal bus error
|
||
|
$ bit1 = Config error
|
||
|
$ bit2 = reserved
|
||
|
$ bit3 = Diagnosis
|
||
|
$ bit4 = reserved
|
||
|
$ bit5 = reserved
|
||
|
$ bit6 = Bus Sense Error
|
||
|
$ bit7 = Fieldbus error / idle mode
|
||
|
|
||
|
|
||
|
|
||
|
$ Output Connections
|
||
|
$ Assemblies
|
||
|
|
||
|
|
||
|
Output1=
|
||
|
6, $ 6 bytes length
|
||
|
0, $ all bits are significant
|
||
|
0x000D, $ Poll, BitStrobe, Change of State and Cyclic
|
||
|
"Control + DataOut", $ Name
|
||
|
6, "20 04 24 B6 30 03", $ Profile Assembly Inst. 182
|
||
|
"Mapping, see EDS-File or Manual"; $ Help String
|
||
|
|
||
|
$ Mapping Info:
|
||
|
$ Channel 1: Byte0 : Control Register Communication Channnel 1
|
||
|
$ Byte1 : DataOut Low Byte Channel 1
|
||
|
$ Byte2 : DataOut High Byte Channel 1
|
||
|
$ Channel 2: Byte3 : Control Register Communication Channnel 2
|
||
|
$ Byte4 : DataOut Low Byte Channel 2
|
||
|
$ Byte5 : DataOut High Byte Channel 2
|
||
|
|
||
|
|
||
|
|
||
|
[ParamClass]
|
||
|
MaxInst = 11;
|
||
|
Descriptor = 0x0001;
|
||
|
CfgAssembly = 0;
|
||
|
|
||
|
[Params]
|
||
|
|
||
|
|
||
|
$ Fieldbus Box Status
|
||
|
|
||
|
Param1=
|
||
|
0,
|
||
|
6, "20 64 24 01 30 05",
|
||
|
0x0032, 24, 1,
|
||
|
"FB Box Status",
|
||
|
"",
|
||
|
"Status of the FB Box",
|
||
|
0, 0xFF, 0,
|
||
|
1, 1, 1, 0,
|
||
|
0, 0, 0, 0,
|
||
|
0;
|
||
|
|
||
|
$ IO Error Action
|
||
|
|
||
|
Param2=
|
||
|
0,
|
||
|
6, "20 64 24 01 30 0A",
|
||
|
0x0003, 8, 1,
|
||
|
"IO Error Action",
|
||
|
"",
|
||
|
"Action to be performed if a Fieldbus Error occurs",
|
||
|
0, 2, 1,
|
||
|
1, 1, 1, 0,
|
||
|
0, 0, 0, 0,
|
||
|
0;
|
||
|
|
||
|
$ Bus Off Behaviour
|
||
|
|
||
|
Param3=
|
||
|
0,
|
||
|
6, "20 64 24 01 30 19",
|
||
|
0x0003, 4, 1,
|
||
|
"Bus Off Behavior",
|
||
|
"",
|
||
|
"Behavior after Bus Off Event",
|
||
|
0, 1, 0,
|
||
|
1, 1, 1, 0,
|
||
|
0, 0, 0, 0,
|
||
|
0;
|
||
|
|
||
|
$ IO Data Sizes
|
||
|
|
||
|
Param4=
|
||
|
0,
|
||
|
6, "20 64 24 01 30 0F",
|
||
|
0x0010, 2, 2,
|
||
|
"Input Size Poll Mode",
|
||
|
"Byte",
|
||
|
"Number of bytes produced via the poll mode",
|
||
|
0, 7, 7,
|
||
|
1, 1, 1, 0,
|
||
|
0, 0, 0, 0,
|
||
|
0;
|
||
|
|
||
|
|
||
|
Param5=
|
||
|
0,
|
||
|
6, "20 64 24 01 30 10",
|
||
|
0x0010, 2, 2,
|
||
|
"Input Size COS/Cyc Mode",
|
||
|
"Byte",
|
||
|
"Number of Bytes produced via Change of State/Cyclic Mode",
|
||
|
0, 7, 7,
|
||
|
1, 1, 1, 0,
|
||
|
0, 0, 0, 0,
|
||
|
0;
|
||
|
|
||
|
Param6=
|
||
|
0,
|
||
|
6, "20 64 24 01 30 12",
|
||
|
0x0010, 2, 2,
|
||
|
"Output Size Poll/COS/Cyc Mode",
|
||
|
"Byte",
|
||
|
"Number of Bytes consumed via Poll/Change of State/Cyclic Mode",
|
||
|
0, 6, 6,
|
||
|
1, 1, 1, 0,
|
||
|
0, 0, 0, 0,
|
||
|
0;
|
||
|
|
||
|
|
||
|
$ Register communication
|
||
|
|
||
|
Param7=
|
||
|
0,
|
||
|
6, "20 64 24 01 30 01",
|
||
|
0x0002, 8, 1,
|
||
|
"Terminal No.",
|
||
|
"",
|
||
|
"module whose register entry is to be read or written",
|
||
|
0, 1, 0,
|
||
|
1, 1, 1, 0,
|
||
|
0, 0, 0, 0, 0 ;
|
||
|
|
||
|
|
||
|
Param8=
|
||
|
0,
|
||
|
6, "20 64 24 01 30 02",
|
||
|
0x0002, 8, 1,
|
||
|
"Table No.",
|
||
|
"",
|
||
|
"Table whose register entry is to be read or written",
|
||
|
0, 100, 0,
|
||
|
1, 1, 1, 0,
|
||
|
0, 0, 0, 0, 0 ;
|
||
|
|
||
|
Param9=
|
||
|
0,
|
||
|
6, "20 64 24 01 30 03",
|
||
|
0x0000, 8, 1,
|
||
|
"Register No.",
|
||
|
"",
|
||
|
"Register entry that is to be read or written.",
|
||
|
0, 255, 0,
|
||
|
1, 1, 1, 0,
|
||
|
0, 0, 0, 0, 0 ;
|
||
|
|
||
|
Param10=
|
||
|
0,
|
||
|
6, "20 64 24 01 30 04",
|
||
|
0x0010, 25,4,
|
||
|
"Get Register data+status",
|
||
|
"",
|
||
|
"Data (Bytes 2+3),\nStatus (Bytes 0+1)\n0xddddssss,d=data,s=status",
|
||
|
0, 0xFFFFFFFF, 0,
|
||
|
1, 1, 1, 0,
|
||
|
0, 0, 0, 0, 0 ;
|
||
|
|
||
|
Param11=
|
||
|
0,
|
||
|
6, "20 64 24 01 30 04",
|
||
|
0x0000,25, 4,
|
||
|
"Set Register data",
|
||
|
"",
|
||
|
"Data (Bytes 0+1),\nReserved (Bytes 2+3)\n0xxxxxdddd,d=data,x=res.",
|
||
|
0, 0xFFFFFFFF, 0,
|
||
|
1, 1, 1, 0,
|
||
|
0, 0, 0, 0, 0 ;
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
[EnumPar]
|
||
|
|
||
|
$ Fieldbus Box Status
|
||
|
|
||
|
Param1=
|
||
|
"FB Box Bus Error",
|
||
|
"Configuration Error FB Box",
|
||
|
"res.",
|
||
|
"Diagnosis",
|
||
|
"res.",
|
||
|
"res.",
|
||
|
"res.",
|
||
|
"DeviceNet Error / Idle State";
|
||
|
|
||
|
|
||
|
$ IO Error Action
|
||
|
|
||
|
Param2=
|
||
|
"Leave Local I/O Cycle",
|
||
|
"Leave Local I/O Cycle + Reset Outputs",
|
||
|
"Freeze Outputs";
|
||
|
|
||
|
|
||
|
$ Bus Off Behaviour
|
||
|
|
||
|
Param3=
|
||
|
"Hold CAN in BusOff",
|
||
|
"Reset Communication/Device";
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
$ Register communication
|
||
|
|
||
|
Param7=
|
||
|
"FB Box ",
|
||
|
"1. Terminal ";
|
||
|
|
||
|
|
||
|
Param8=
|
||
|
"Table 0: FB Box or 1. Channel Term.",
|
||
|
"Table 1: FB Box or 2. Channel Term.",
|
||
|
"Table 2: FB Box or 3. Channel Term.",
|
||
|
"Table 3: FB Box or 4. Channel Term.",
|
||
|
"Table 4: (reserved)",
|
||
|
"Table 5: (reserved)",
|
||
|
"Table 6: (reserved)",
|
||
|
"Table 7: (reserved)",
|
||
|
"Table 8: (reserved)",
|
||
|
"Table 9: (reserved)",
|
||
|
"Table 10: (reserved)",
|
||
|
"Table 11: (reserved)",
|
||
|
"Table 12: (reserved)",
|
||
|
"Table 13: (reserved)",
|
||
|
"Table 14: (reserved)",
|
||
|
"Table 15: (reserved)",
|
||
|
"Table 16: (reserved)",
|
||
|
"Table 17: (reserved)",
|
||
|
"Table 18: (reserved)",
|
||
|
"Table 19: (reserved)",
|
||
|
"Table 20: (reserved)",
|
||
|
"Table 21: (reserved)",
|
||
|
"Table 22: (reserved)",
|
||
|
"Table 23: (reserved)",
|
||
|
"Table 24: (reserved)",
|
||
|
"Table 25: (reserved)",
|
||
|
"Table 26: (reserved)",
|
||
|
"Table 27: (reserved)",
|
||
|
"Table 28: (reserved)",
|
||
|
"Table 29: (reserved)",
|
||
|
"Table 30: (reserved)",
|
||
|
"Table 31: (reserved)",
|
||
|
"Table 32: (reserved)",
|
||
|
"Table 33: (reserved)",
|
||
|
"Table 34: (reserved)",
|
||
|
"Table 35: (reserved)",
|
||
|
"Table 36: (reserved)",
|
||
|
"Table 37: (reserved)",
|
||
|
"Table 38: (reserved)",
|
||
|
"Table 39: (reserved)",
|
||
|
"Table 40: (reserved)",
|
||
|
"Table 41: (reserved)",
|
||
|
"Table 42: (reserved)",
|
||
|
"Table 43: (reserved)",
|
||
|
"Table 44: (reserved)",
|
||
|
"Table 45: (reserved)",
|
||
|
"Table 46: (reserved)",
|
||
|
"Table 47: (reserved)",
|
||
|
"Table 48: (reserved)",
|
||
|
"Table 49: (reserved)",
|
||
|
"Table 50: (reserved)",
|
||
|
"Table 51: (reserved)",
|
||
|
"Table 52: (reserved)",
|
||
|
"Table 53: (reserved)",
|
||
|
"Table 54: (reserved)",
|
||
|
"Table 55: (reserved)",
|
||
|
"Table 56: (reserved)",
|
||
|
"Table 57: (reserved)",
|
||
|
"Table 58: (reserved)",
|
||
|
"Table 59: (reserved)",
|
||
|
"Table 60: (reserved)",
|
||
|
"Table 61: (reserved)",
|
||
|
"Table 62: (reserved)",
|
||
|
"Table 63: (reserved)",
|
||
|
"Table 64: (reserved)",
|
||
|
"Table 65: (reserved)",
|
||
|
"Table 66: (reserved)",
|
||
|
"Table 67: (reserved)",
|
||
|
"Table 68: (reserved)",
|
||
|
"Table 69: (reserved)",
|
||
|
"Table 70: (reserved)",
|
||
|
"Table 71: (reserved)",
|
||
|
"Table 72: (reserved)",
|
||
|
"Table 73: (reserved)",
|
||
|
"Table 77: (reserved)",
|
||
|
"Table 75: (reserved)",
|
||
|
"Table 76: (reserved)",
|
||
|
"Table 77: (reserved)",
|
||
|
"Table 78: (reserved)",
|
||
|
"Table 79: (reserved)",
|
||
|
"Table 80: (reserved)",
|
||
|
"Table 81: (reserved)",
|
||
|
"Table 82: (reserved)",
|
||
|
"Table 83: (reserved)",
|
||
|
"Table 84: (reserved)",
|
||
|
"Table 85: (reserved)",
|
||
|
"Table 86: (reserved)",
|
||
|
"Table 87: (reserved)",
|
||
|
"Table 88: (reserved)",
|
||
|
"Table 89: (reserved)",
|
||
|
"Table 90: FB Box diagnosis",
|
||
|
"Table 91: process image diagnosis",
|
||
|
"Table 92: (reserved)",
|
||
|
"Table 93: (reserved)",
|
||
|
"Table 94: (reserved)",
|
||
|
"Table 95: (reserved)",
|
||
|
"Table 96: (reserved)",
|
||
|
"Table 97: (reserved)",
|
||
|
"Table 98: (reserved)",
|
||
|
"Table 99: FB Box function calls",
|
||
|
"Table 100: DeviceNet configuration";
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
[Groups]
|
||
|
|
||
|
Group1=
|
||
|
"FB Box common", 3,
|
||
|
1,2,3;
|
||
|
|
||
|
Group2=
|
||
|
"Data Sizes", 3,
|
||
|
4,5,6;
|
||
|
|
||
|
Group3=
|
||
|
"Register Communication", 5,
|
||
|
7,8,9,10,11;
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
[108_TwinCAT]
|
||
|
DeviceImage = "Ip.bmp";
|
||
|
VendorImage = "Beckhoff.bmp";
|
||
|
KBusSupport = 0;
|
||
|
PLCSupport = 0;
|
||
|
FirmwareFlashable = 1;
|
||
|
ComplexTerminals = 1;
|
||
|
NoCouplerState = 0;
|
||
|
FbbSupport = 1;
|
||
|
LinkSupport = 0;
|
||
|
DefaultTerm0 = 1677724102; $ 0x64000000 + 2502
|
||
|
ValidTerm0 = 1677724102; $ 0x64000000 + 2502
|
||
|
Comment = "PWM Compact Box";
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
|
$ Default IO-Mapping Information
|
||
|
$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
|
$
|
||
|
$ Input Data
|
||
|
$
|
||
|
$ Mapping Info:
|
||
|
$ Channel 1: Byte0 : Status Register Communication Channnel 1
|
||
|
$ Byte1 : DataIn Low Byte Channel 1
|
||
|
$ Byte2 : DataIn High Byte Channel 1
|
||
|
$ Channel 2: Byte3 : Status Register Communication Channnel 2
|
||
|
$ Byte4 : DataIn Low Byte Channel 2
|
||
|
$ Byte5 : DataIn High Byte Channel 2
|
||
|
$ Byte6:(vendor specific status byte)
|
||
|
$ bit0 = Internal bus error
|
||
|
$ bit1 = Config error
|
||
|
$ bit2 = reserved
|
||
|
$ bit3 = Diagnosis
|
||
|
$ bit4 = reserved
|
||
|
$ bit5 = reserved
|
||
|
$ bit6 = Bus Sense Error
|
||
|
$ bit7 = Fieldbus error / idle mode
|
||
|
$
|
||
|
$ Output Data
|
||
|
$
|
||
|
$ Mapping Info:
|
||
|
$ Channel 1: Byte0 : Control Register Communication Channnel 1
|
||
|
$ Byte1 : DataOut Low Byte Channel 1
|
||
|
$ Byte2 : DataOut High Byte Channel 1
|
||
|
$ Channel 2: Byte3 : Control Register Communication Channnel 2
|
||
|
$ Byte4 : DataOut Low Byte Channel 2
|
||
|
$ Byte5 : DataOut High Byte Channel 2
|