'Bedingte Lüfterauswertung beim CP6500/CP7503 (drehzahlgeregelter Prozessorlüfter) ' Lüfterdrehzahl wird erst ab 35°C ausgewertet Option Explicit Dim wshshell,fso,i,Fnct Dim strPath,strSystemFolder,strWinFolder,strTempFolder '----------------------------- Objekte erzeugen -------------------------------- i = 0 On Error Resume Next Do err.Clear i = i+1 Set wshshell = CreateObject("WScript.Shell") Set fso = CreateObject("Scripting.FileSystemObject") Set Fnct = CreateObject("Install.Functions") WScript.Sleep 1000 Loop Until Err.Number = 0 OR i > 30 If Err.Number <> 0 Then WScript.Quit End If On Error Goto 0 '--------------------------- Standardpfade ------------------------------------- strPath = GetCurrentPath() strSystemFolder = fso.GetSpecialFolder(1) & "\" strWinFolder = fso.GetSpecialFolder(0) & "\" strTempFolder = fso.GetSpecialFolder(2) & "\" '------------------------------ Main ------------------------------------------- Dim strMainVolume Dim strComputerIni strMainVolume = ExpandPath("%MAIN_VOLUME%","c:\") strComputerIni = strMainVolume & "Computer.ini" Dim strComputerType strComputerType = Fnct.GetIniString("CD1_Setup","ComputerType",strComputerIni) 'Nur bei diesem Computertyp If strComputerType = "CP6500-1003-0020" Or strComputerType = "CP7503-1002-0020" Then Call Fnct.SetIniString("MBProbe","Fan1_CondVar","Temp1",strComputerIni) Call Fnct.SetIniString("MBProbe","Fan1_CondVal","35",strComputerIni) Call Fnct.SetIniString("MBProbe","Fan1_CondEval","2",strComputerIni) End If '------------------------------- Funktionen ------------------------------------ Function GetCurrentPath() Dim l_strScriptName Dim l_strTemp l_strScriptName = WScript.ScriptFullName l_strTemp = WScript.ScriptName GetCurrentPath = Left(l_strScriptName, Len(l_strScriptName) - Len(l_strTemp)) End Function Function ExpandPath(p_strEnvironment,p_strDefault) Dim l_strTemp l_strTemp = wshshell.ExpandEnvironmentStrings(p_strEnvironment) If l_strTemp = p_strEnvironment Then l_strTemp = p_strDefault End If ExpandPath = l_strTemp End Function