; ;====================================================== ; GSD-file for PROFIBUS-DP Coupler/SPC3 ; Manufacturer: Beckhoff Automation GmbH ; Eiserstr. 5 ; 33415 Verl (Germany) ; Tel.: +49(0)5246/963-0 ; stock-nr.: IP20xx-B310 ; state: 02.06.06 ; ; ;----------------------- TwinCAT ---------------------- ; Tc_KBus_supp = 1 ; Bus-Coupler Tc_Plc_supp = 0 ; Bus-Controller Tc_Fbb_supp = 1 ; Fieldbus Box Tc_Firmware_Flashable = 1 ; Tc_Valid_Term(0) = 1677723600 ; 0x64000000 + 2000 Tc_Valid_Term(1) = 1677723601 ; 0x64000000 + 2001 Tc_Valid_Term(2) = 1677723602 ; 0x64000000 + 2002 Tc_Valid_Term(3) = 1677723620 ; 0x64000000 + 2020 Tc_Valid_Term(4) = 1677723621 ; 0x64000000 + 2021 Tc_Valid_Term(5) = 1677723622 ; 0x64000000 + 2022 Tc_Valid_Term(6) = 1677723640 ; 0x64000000 + 2040 Tc_Valid_Term(7) = 1677723641 ; 0x64000000 + 2041 Tc_Valid_Term(8) = 1677723642 ; 0x64000000 + 2042 Tc_Comment = "Digital Output Compact Box" Tc_BitmapFile = "Ip.bmp" Tc_VendorBitmapFile = "Beckhoff.bmp" ; ;------------------------- DP ------------------------- ; #Profibus_DP ; ;------------------ PrmText-Definitionen -------------- ; PrmText = 1 Text(0) = "is not active" Text(1) = "is active" EndPrmText PrmText = 12 Text(0) = "Synchron" Text(1) = "FreeRun" EndPrmText PrmText = 13 Text(0) = "Cycle stopped" Text(1) = "outputs to 0" Text(2) = "outputs remain equal" EndPrmText ; ;------------- ExtUserPrmData-Definitionen -------------- ; ExtUserPrmData = 12 "Updating of process image" Bit(6) 1 0-1 Prm_Text_Ref = 12 EndExtUserPrmData ExtUserPrmData = 13 "Reaction on DP-Error" BitArea(0-1) 0 0-2 Prm_Text_Ref = 13 EndExtUserPrmData ExtUserPrmData = 86 "Fast FreeRun-Mode" Bit(4) 0 0-1 Prm_Text_Ref = 1 EndExtUserPrmData ; ;---------------------- DP-General --------------------- ; GSD_Revision = 2 Vendor_Name = "BECKHOFF" Model_Name = "IP20xx-B3xx" Revision = "Revision 3.2" Ident_Number = 0x0517 Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "08" Software_Release = "B3" 9.6_supp = 1 19.2_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 350 MaxTsdr_12M = 550 Redundancy = 0 Repeater_Ctrl_Sig = 0 24V_Pins = 0 Implementation_Type = "SPC3" Bitmap_Device = "Ip" ; ;-------------------- DP-Slave ----------------------- ; Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Auto_Baud_supp = 1 Set_Slave_Add_supp = 0 Min_Slave_Intervall = 1 Modular_Station = 0 Fail_Safe = 1 Max_Diag_Data_Len = 64 Slave_Family = 3 ; ;---------------------- DPV1 ------------------------- ; ; ;------------------- UserPrmData --------------------- ; Max_User_Prm_Data_Len = 15 Ext_User_Prm_Data_Const(0) = 0x00 Ext_User_Prm_Data_Const(1) = 0x00 Ext_User_Prm_Data_Const(2) = 0x08 Ext_User_Prm_Data_Const(3) = 0x00 Ext_User_Prm_Data_Const(4) = 0x00 Ext_User_Prm_Data_Const(5) = 0x00 Ext_User_Prm_Data_Const(6) = 0x00 Ext_User_Prm_Data_Const(7) = 0x40 Ext_User_Prm_Data_Const(8) = 0x00 Ext_User_Prm_Data_Const(9) = 0x63 Ext_User_Prm_Data_Ref(9) = 86 Ext_User_Prm_Data_Ref(9) = 12 Ext_User_Prm_Data_Const(10) = 0x00 Ext_User_Prm_Data_Ref(10) = 13 Ext_User_Prm_Data_Const(11) = 0x40 Ext_User_Prm_Data_Const(12) = 0x00 Ext_User_Prm_Data_Const(13) = 0x00,0x00 ; ;-------------------- Modules ------------------------ ; Module = "8 Bit digital outputs" 0x20 155 EndModule