| Option Explicit
 | |
| Dim wshshell
 | |
| Dim fso
 | |
| 'Dim MachineType
 | |
| 'Dim MachineNumber
 | |
| Dim FileName
 | |
| Dim IpString
 | |
| Dim RtsCount
 | |
| Dim i
 | |
| Dim Fnct
 | |
| Dim Key,TmpKey
 | |
| 
 | |
| set wshshell = CreateObject("WScript.Shell")
 | |
| Set Fnct = CreateObject("Install.Functions")
 | |
| 
 | |
| GetInputs
 | |
| key = "HKEY_LOCAL_MACHINE\SOFTWARE\Beckhoff\TwinCAT\System\SysAutoStart"
 | |
| wshshell.RegWrite key,1,"REG_DWORD"
 | |
| key = "HKEY_LOCAL_MACHINE\SOFTWARE\Beckhoff\TwinCAT\System\SysStartupState"
 | |
| wshshell.RegWrite key,5,"REG_DWORD"
 | |
| key = "HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\TcIo\Start"
 | |
| wshshell.RegWrite key,2,"REG_DWORD"
 | |
| key = "HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\TcNc\Start"
 | |
| wshshell.RegWrite key,2,"REG_DWORD"
 | |
| key = "HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\TcPlc\Start"
 | |
| wshshell.RegWrite key,2,"REG_DWORD"
 | |
| key = "HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\TcRouter\Start"
 | |
| wshshell.RegWrite key,2,"REG_DWORD"
 | |
| key = "HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\TcRTime\Start"
 | |
| wshshell.RegWrite key,2,"REG_DWORD"
 | |
| 
 | |
| 
 | |
| 'Call wshshell.Run("""" & GetCurrentPath()+"WriteAmsNetId.exe"" IP 150.150.98."+IPString)
 | |
| For i = 1 To RtsCount
 | |
| 	Key = "HKEY_LOCAL_MACHINE\SOFTWARE\Beckhoff\TwinCAT\System\build"
 | |
| 	If wshshell.RegRead(key) >= 718 Then
 | |
| 		Key = "HKEY_LOCAL_MACHINE\SOFTWARE\Beckhoff\TwinCAT\Plc\LoadBootPrjRetainData" & CStr(i)
 | |
| 		wshshell.RegWrite key,1,"REG_DWORD"
 | |
| 	Else
 | |
| 		Key = "HKEY_LOCAL_MACHINE\SOFTWARE\Beckhoff\TwinCAT\Init8\PLC: Load Boot Project\"
 | |
| 		TmpKey = Key + "Cmd" + CStr(i)
 | |
| 		wshshell.RegWrite TmpKey,20483,"REG_DWORD"
 | |
| 		TmpKey = Key + "Port" + CStr(i)
 | |
| 		wshshell.RegWrite TmpKey,801 + (i-1)*10,"REG_DWORD"
 | |
| 		TmpKey = Key + "Str" + CStr(i)
 | |
| 		wshshell.RegWrite TmpKey,0,"REG_BINARY"
 | |
| 		TmpKey = Key + "Msg" + CStr(i)
 | |
| 		wshshell.RegWrite TmpKey,"PLC Boot Project of Run-Time System " + CStr(i) + " loaded"
 | |
| 	End If
 | |
| Next
 | |
| 
 | |
| Sub GetInputs
 | |
|     Dim fso
 | |
|     Dim CompFile
 | |
| 	IpString = ""
 | |
|     Set fso = CreateObject("Scripting.FileSystemObject")
 | |
|     If fso.FileExists("c:\Computer.ini") Then
 | |
|     	IPString = Fnct.GetIniString("CD1_Setup", "TcpIp", "c:\Computer.ini")
 | |
|     	RtsCount = Fnct.GetIniString("CD1_Setup", "RtsCount", "c:\Computer.ini")
 | |
|     End If
 | |
| 	If fso.FileExists("c:\Computer.txt") And IpString = "" Then
 | |
|     	Set CompFile = fso.OpenTextFile("c:\Computer.txt", 1)
 | |
| 	    IPString = CompFile.ReadLine
 | |
| 	    RtsCount = CompFile.ReadLine
 | |
| 	    CompFile.Close
 | |
|     End If
 | |
| end sub
 | |
| 
 | |
| Function GetCurrentPath()
 | |
|     Dim l_strScriptName
 | |
|     Dim l_strTemp
 | |
| 
 | |
|     l_strScriptName = WScript.ScriptFullName
 | |
|     l_strTemp = WScript.ScriptName
 | |
|     GetCurrentPath = Left(l_strScriptName, Len(l_strScriptName) - Len(l_strTemp))
 | |
| End Function
 |