Parametertext ;Do not change these 3 lines
Version = 12.04.06 ;Version of contents
Syntax = 01 ;Version of Syntax
;---------------------------------------------------------------------------------------------------------------
;PNR TEXTROT TEXTLIN [TOGROT] [TOGLIN]
;---------------------------------------------------------------------------------------------------------------
1 "Actual traversing block - block number" "" {T0}
2 "Actual traversing block - position" "" {T0}
3 "Actual traversing block - velocity" "" {T0}
4 "Actual traversing block - acceleration override" "" {T0}
5 "Actual traversing block - deceleration override" "" {T0}
6 "Actual traversing block - command" "" {T0}
7 "Actual traversing block - command parameter" "" {T0}
8 "Actual traversing block - mode" "" {T0}
20 "Position setpoint" "" {T0}
21 "Position actual value" "" {T0}
22 "Distance to go" "" {T0}
23 "Velocity setpoint" "" {T0}
24 "Actual velocity" "" {T0}
25 "Effective override" "" {T0}
26 "Position actual value, external block change" "" {T0}
29 "Following error" "" {T0}
30 "Control deviation, position controller input" "" {T0}
31 "Actual Kv factor (position loop gain)" "" {T0}
32 "Position reference value, external" "" {T0}
79 "Reformat memory" "" {T0}
80 "Block number" "" {T0}
81 "Position" "" {T0}
82 "Velocity" "" {T0}
83 "Acceleration override" "" {T0}
84 "Deceleration override" "" {T0}
85 "Command" "" {T0}
86 "Command parameter" "" {T0}
87 "Mode" "" {T0}
91 "MDI position" "" {T0}
92 "MDI velocity" "" {T0}
93 "MDI acceleration override" "" {T0}
94 "MDI deceleration override" "" {T0}
97 "MDI mode" "" {T0}
100 "Dimension system" "" {T0}
101 "Actual dimension system" "" {T0}
102 "Maximum motor velocity" "" {T0}
103 "Maximum acceleration" "" {T0}
104 "Maximum deceleration" "" {T0}
105 "Override via SimoCom U" "" {T0}
106 "Time override active" "" {T0}
107 "Jerk limiting" "" {T0}
108 "Velocity setpoint jog 1" "" {T0}
109 "Velocity setpoint jog 2" "" {T0}
110 "Configuration, external block change" "" {T0}
111 "Normalization voltage, override" "" {T0}
112 "Normalization of override" "" {T0}
113 "Fixed endstop, configuration 1" "" {T0}
113b0 "Characteristics for the fixed endstop not reached" "" {T0}
113b1 "Characteristics for the clamping torque not reached" "" {T0}
114 "Fixed endstop, configuration 2" "" {T0}
115 "Fixed endstop, maximum following error" "" {T0}
116 "Fixed endstop, monitoring window" "" {T0}
118 "Software limit switch configuration" "" {T0}
118b0 "Behavior for software limit switch reached" "" {T0}
120 "Teach-in block" "" {T0}
121 "Teach-in standard block" "" {T0}
122 "Jogging 1 increments" "" {T0}
123 "Jogging 2 increments" "" {T0}
124 "Teach-in configuration" "" {T0}
124b0 "Automatic block change enable" "" {T0}
124b1 "Automatic block search" "" {T0}
125 "Spindle positioning active" "" {T0}
126 "Spindle positioning, zero mark tolerance window (BERO)" "" {T0}
127 "Spindle positioning, setting the internal zero mark" "" {T0}
128 "Spindle positioning offset, zero" "" {T0}
129 "Spindle positioning, tolerance search velocity" "" {T0}
130 "Spindle positioning, lowest search velocity" "" {T0}
131 "Spindle positioning, motion window" "" {T0}
132 "Spindle positioning, zero mark difference (BERO)" "" {T0}
133 "Spindle positioning, max. search velocity" "" {T0}
134 "Spindle positioning, positioning window reached" "" {T0}
136 "Spindle positioning active/inative" "" {T0}
137 "Spindle positioning status" "" {T0}
160 "Reference point coordinate" "" {T0}
162 "Reference point offset" "" {T0}
163 "Reference point approach velocity" "" {T0}
164 "Reference point creep speed" "" {T0}
165 "Reference point entry velocity" "" {T0}
166 "Reference cam approach direction" "" {T0}
167 "Invert, reference cams" "" {T0}
170 "Maximum distance to the reference cam" "" {T0}
171 "Max. distance between reference cam and zero pulse" "" {T0}
172 "Distance between reference cam and zero pulse" "" {T0}
173 "Reference point approach without reference cams" "" {T0}
174 "Referencing mode, position measuring system" "" {T0}
175 "Adjustment status - absolute position measuring system" "" {T0}
176 "Absolute encoder offset" "" {T0}
177 "Absolute encoder offset, low part" "" {T0}
178 "Absolute encoder offset, high part" "" {T0}
179 "mode, passive referencing" "" {T0}
200 "Kv factor (position loop gain)" "" {T0}
201 "backlash compensation" "" {T0}
203 "speed feedforward control mode" "" {T0}
204 "speed feedforward control factor" "" {T0}
205 "Balancing filter, speed feedforward control (deadtime)" "" {T0}
206 "Balancing filter, speed feedforward control (PT1)" "" {T0}
210 "Time constant, position setpoint filter" "" {T0}
231 "Position actual value inversion" "" {T0}
232 "Position setpoint inversion" "" {T0}
236 "Spindle pitch" "" {T0}
237 "Encoder revolutions" "" {T0}
238 "Load revolutions" "" {T0}
239 "Re-reference or re-adjust only if necessary" "" {T0}
241 "Activating, modulo conversion, rotary axis" "" {T0}
242 "Modulo range, rotary axis" "" {T0}
250 "Activate direct measuring system" "" {T0}
310 "Cam switching position 1" "" {T0}
311 "Cam switching position 2" "" {T0}
314 "Activating software limit switch" "" {T0}
315 "Minus software limit switch" "" {T0}
316 "Plus software limit switch" "" {T0}
318 "Dynamic following error monitoring tolerance" "" {T0}
320 "Position monitoring time" "" {T0}
321 "Positioning window" "" {T0}
325 "Standstill monitoring time" "" {T0}
326 "Standstill window" "" {T0}
400 "Reference point coordinates, master drive" "" {T0}
401 "Coupling factor, master drive revolutions" "" {T0}
402 "Coupling factor slave drive revolutions" "" {T0}
403 "Actual coupling factor, master drive revolutions" "" {T0}
404 "Actual coupling factor, slave drive revolutions" "" {T0}
410 "Configuration, coupling which can be switched-in" "" {T0}
412 "Synchronous offset position" "" {T0}
413 "Offset, synchronous velocity" "" {T0}
420 "Pos. difference, meas. probe to the zero point, slave drive" "" {T0}
425 "Coupling positions" "" {T0}
599 "Active motor data set" "" {T0}
600 "Operating display" "" {T0}
600b0 " " "" {T0}
600b1 " " "" {T0}
600b2 " " "" {T0}
600b3 " " "" {T0}
600b4 " " "" {T0}
600b5 " " "" {T0}
600b6 " " "" {T0}
600b7 " " "" {T0}
600b8 " " "" {T0}
600b9 " " "" {T0}
600b10 " " "" {T0}
600b11 " " "" {T0}
600b12 " " "" {T0}
600b13 " " "" {T0}
600b14 " " "" {T0}
600b15 " " "" {T0}
600b16 " " "" {T0}
600b17 " " "" {T0}
600b18 " " "" {T0}
600b19 " " "" {T0}
600b20 " " "" {T0}
600b21 " " "" {T0}
600b22 " " "" {T0}
600b23 " " "" {T0}
601 "Motor speed setpoint" "Velocity setpoint, motor" {T0}
602 "Actual motor speed" "Velocity actual value, motor" {T0}
603 "Motor temperature" "" {T0}
604 "Utilization, motor" "" {T0}
606 "Voltage at term. 56.x/14.x" "" {T0}
607 "Analog setpoint term. 56.x/14.x" "" {T0}
608 "Inversion term. 56.x/14.x" "" {T0}
609 "Smoothing time, terminal 56.x/14.x" "" {T0}
610 "Drift/offset correction term. 56.x/14.x" "" {T0}
611 "Voltage at term. 24.x/20.x" "" {T0}
612 "Analog setpoint term. 24.x/20.x" "" {T0}
613 "Inversion term. 24.x/20.x" "" {T0}
614 "Smoothing time, terminal 24.x/20.x" "" {T0}
615 "Drift/offset correction term. 24.x/20.x" "" {T0}
616 "Ramp-function generator ramp-up time" "" {T0}
617 "Ramp-function generator ramp-down time" "" {T0}
618 "Normalization voltage, speed setpoint" "" {T0}
619 "Normalization voltage, torque setpoint" "" {T0}
620 "Normalization voltage, torque/power reduction." "Normalization voltage, force/power reduction" {T0}
623 "DAC normalization, actual speed" "DAC normalization, motor actual velocity" {T0}
624 "DAC normalization, motor utilization" "" {T0}
625 "DAC normalization, torque setpoint" "DAC normalization, force setpoint" {T0}
626 "Signal number analog output term. 75.x/15" "" {T0}
627 "Shift factor analog output term. 75.x/15" "" {T0}
628 "Offset analog output term. 75.x/15" "" {T0}
629 "Segment address analog output term. 75.x/15" "" {T0}
630 "Offset address analog output term. 75.x/15" "" {T0}
631 "Bias protection, analog output, term. 75.x/15" "" {T0}
632 "Smoothing time, analog output, terminal 75.x/15" "" {T0}
633 "Signal number analog output term. 16.x/15" "" {T0}
634 "Shift factor analog output term. 16.x/15" "" {T0}
635 "Offset analog output term. 16.x/15" "" {T0}
636 "Segment address analog output term. 16.x/15" "" {T0}
637 "Offset address analog output term. 16.x/15" "" {T0}
638 "Bias protection, analog output, term. 16.x/15" "" {T0}
639 "Smoothing time, analog output, terminal 15.x/15" "" {T0}
641 "Fixed speed setpoint" "Fixed velocity setpoint" {T0}
649 "Delete parameters, drives A and B" "" {T0}
651 "Read and write protection" "" {T0}
652 "Transfer to FEPROM" "" {T0}
653 "Image, input signals, Part 1" "" {T0}
653b0 "ON / OFF1" "" {T0}
653b1 "Operating condition / OFF2" "" {T0}
653b2 "Operating condition / OFF3" "" {T0}
653b3 "Enable inverter/pulse inhibit" "" {T0}
653b4 "Ramp-fct.generator enable or OC/reject traversing task" "" {T0}
653b5 "Ramp-function generator start/stop or OC/intermed. stop" "" {T0}
653b6 "Enable setpoint and activate traversing task (edge)" "" {T0}
653b7 "Reset fault memory" "" {T0}
653b8 "Jog 1 ON / OFF" "" {T0}
653b9 "Jog 2 ON / OFF" "" {T0}
653b10 "Control requested / no control requested" "" {T0}
653b11 "Start referencing / exit referencing" "" {T0}
653b12 "Open holding braking as test/do no open" "" {T0}
653b13 "Ramp-up time zero w. control.enable or ext. block change" "" {T0}
653b14 "Open-loop torque controlled operation" "" {T0}
653b15 "Spindle positioning on or request passive referencing" "" {T0}
653b16 "Signal status, terminal 65.x" "" {T0}
653b17 "NE signal status, terminal 64" "" {T0}
653b18 "Signal status terminal 663 / terminal IF" "" {T0}
653b19 "NE signal status, terminal 63 / terminal 48" "" {T0}
653b21 "Equivalent zero mark" "" {T0}
653b22 "Flying measurement / length measurement" "" {T0}
654 "Image, input signals, Part 2" "" {T0}
654b0 "Parameter set switchover bit 0" "" {T0}
654b1 "Parameter set switchover bit 1" "" {T0}
654b2 "Parameter set switchover bit 2" "" {T0}
654b3 "First speed setpoint filter off" "" {T0}
654b4 "Ramp-up time zero" "" {T0}
654b5 "Siemens reserved (radial eccentricity monitoring)" "" {T0}
654b6 "Integrator disable speed controller" "" {T0}
654b7 "Select parking axis" "" {T0}
654b8 "Suppress fault 608" "" {T0}
654b9 "Motor changeover, bit 0" "" {T0}
654b10 "Motor changeover, bit 1" "" {T0}
654b11 "Motor changed over" "" {T0}
654b12 "Tracking operation" "" {T0}
654b13 "Set reference point" "" {T0}
654b14 "Reference cam" "" {T0}
654b15 "Fixed endstop, sensor" "" {T0}
654b16 "Plus hardware limit switch" "" {T0}
654b17 "Minus hardware limit switch" "" {T0}
654b18 "Fixed speed setpoint and block selection bit 0" "" {T0}
654b19 "Fixed speed setpoint and block selection bit 1" "" {T0}
654b20 "Fixed speed setpoint and block selection bit 2" "" {T0}
654b21 "Fixed speed setpoint and block selection bit 3" "" {T0}
654b22 "Block selection, bit 4" "" {T0}
654b23 "Block selection, bit 5" "" {T0}
655 "Image, input signal Part 3" "" {T0}
655b0 "Activate coupling" "" {T0}
655b1 "Jogging, incremental" "" {T0}
655b2 "Activate teach-in" "" {T0}
655b3 "Invert input pulses, angular encoder interface" "" {T0}
655b15 "Activate MDI" "" {T0}
655b21 "Activate the coupling via I0.x" "" {T0}
655b22 "Set position reference value" "" {T0}
656 "Image, output signals, Part 1" "" {T0}
656b0 "Ready to power-up / not ready to power-up" "" {T0}
656b1 "Ready to run or no fault" "" {T0}
656b2 "Status, controller enable" "" {T0}
656b3 "Fault available / no fault present" "" {T0}
656b4 "No OFF2 / OFF2 effective" "" {T0}
656b5 "No OFF3 / OFF3 effective" "" {T0}
656b6 "Power-on / No power-on inhibit" "" {T0}
656b7 "Alarm effective / No alarm present" "" {T0}
656b8 "n_set = n_act or no following error" "" {T0}
656b9 "Control requested" "" {T0}
656b10 "Comparison value reached or reference position reached" "" {T0}
656b11 "Reference point set / no reference point set" "" {T0}
656b12 "Setpoint acknowledgement (edge)" "" {T0}
656b13 "Fct. generator active or drive is stationary / drive moving" "" {T0}
656b14 "Open-loop torque controlled operation" "" {T0}
656b15 "Spindle positioning on or request passive referencing" "" {T0}
657 "Image, output signals, Part 2" "" {T0}
657b0 "Parameter set bit 0" "" {T0}
657b1 "Parameter set bit 1" "" {T0}
657b2 "Parameter set bit 2" "" {T0}
657b3 "First speed setpoint filter inactive" "" {T0}
657b4 "Ramp-function generator inactive" "" {T0}
657b5 "Open holding brake" "" {T0}
657b6 "Integrator disable speed controller" "" {T0}
657b7 "Parking axis selected" "" {T0}
657b8 "Suppress fault 608 active" "" {T0}
657b9 "Motor changeover, bit 0" "" {T0}
657b10 "Motor changeover, bit 1" "" {T0}
657b11 "Motor changeover running" "" {T0}
657b15 "MDI active" "" {T0}
657b18 "Status, block selection, bit 0" "" {T0}
657b19 "Status, block selection, bit 1" "" {T0}
657b20 "Status, block selection, bit 2" "" {T0}
657b21 "Status, block selection, bit 3" "" {T0}
657b22 "Status, block selection, bit 4" "" {T0}
657b23 "Status, block selection, bit 5" "" {T0}
658 "Image, output signals, Part 3" "" {T0}
658b0 "Ramp-up completed" "" {T0}
658b1 "|M| < M_x (P:1428, P:1429)" "" {T0}
658b2 "|n_act| < n_min (P:1418)" "" {T0}
658b3 "|n_act| < n_x (P:1417)" "" {T0}
658b4 "V_dc link > V_x (P:1604)" "" {T0}
658b5 "Variable signaling function" "" {T0}
658b6 "Motor temperature ok (motor temperature < P:1602)" "" {T0}
658b7 "Heatsink temperature ok" "" {T0}
658b8 "n_set = n_act (P:1426, P:1427)" "" {T0}
658b9 "Fixed endstop reached" "" {T0}
658b10 "Fixed endstop, clamping torque reached" "" {T0}
658b11 "Traverse to endstop active" "" {T0}
658b12 "Tracking active" "" {T0}
658b13 "Velocity limiting active" "" {T0}
658b14 "Setpoint available" "" {T0}
658b15 "Synchronized" "" {T0}
658b16 "Axis traverses forwards" "" {T0}
658b17 "Axis traverses backwards" "" {T0}
658b18 "Minus software limit switch approached" "" {T0}
658b19 "Plus software limit switch approached" "" {T0}
658b20 "Cam switching signal 1" "" {T0}
658b21 "Cam switching signal 2" "" {T0}
658b22 "Direct output 1 via traversing block" "" {T0}
658b23 "Direct output 2 via traversing block" "" {T0}
658b24 "Electronics temperature OK" "" {T0}
658b25 "i2t power section current not limited" "" {T0}
658b26 "Pulsed resistor not overloaded (only for POSMO CA)" "" {T0}
658b27 "Checkback signal, drive enable" "" {T0}
658b28 "Pulses enabled" "" {T0}
658b29 "Position reached" "" {T0}
658b30 "Spindle position 2 reached" "" {T0}
658b31 "Teach-in executed" "" {T0}
659 "Bootstrap loading" "" {T0}
660 "Function of input terminal I0.x" "" {T0}
661 "Function of input terminal I1.x" "" {T0}
662 "Function of input terminal I2.x" "" {T0}
663 "Function of input terminal I3.x" "" {T0}
664 "Function of input terminal I4" "" {T0}
665 "Function of input terminal I5" "" {T0}
666 "Function of input terminal I6" "" {T0}
667 "Function of input terminal I7" "" {T0}
668 "Function of input terminal I8" "" {T0}
669 "Function of input terminal I9" "" {T0}
670 "Function of input terminal I10" "" {T0}
671 "Function of input terminal I11" "" {T0}
672 "Function, input terminal I0.B" "" {T0}
676 "Assignment, inputs: Optional TERMINAL module" "" {T0}
677 "O1.x as input I2.x" "" {T0}
678 "Image of the input terminals" "" {T0}
678b0 "Signal state I0.x" "" {T0}
678b1 "Signal state I1.x" "" {T0}
678b2 "Signal state I2.x" "" {T0}
678b3 "Signal state I3.x" "" {T0}
678b4 "Signal status I4 (optional terminal module)" "" {T0}
678b5 "Signal status I5 (optional terminal module)" "" {T0}
678b6 "Signal status I6 (optional terminal module)" "" {T0}
678b7 "Signal status I7 (optional terminal module)" "" {T0}
678b8 "Signal status I8 (optional terminal module)" "" {T0}
678b9 "Signal status I9 (optional terminal module)" "" {T0}
678b10 "Signal status I10 (optional terminal module)" "" {T0}
678b11 "Signal status I11 (optional terminal module)" "" {T0}
678b12 "Signal status, terminal 65.x" "" {T0}
678b13 "NE signal status, terminal 64" "" {T0}
678b14 "Signal status terminal 663 / terminal IF" "" {T0}
678b15 "NE signal status, terminal 63 / terminal 48" "" {T0}
680 "signaling function of output terminal O0.x" "" {T0}
681 "signaling function of output terminal O1.x" "" {T0}
682 "signaling function of output terminal O2.x" "" {T0}
683 "signaling function of output terminal O3.x" "" {T0}
684 "signaling function, output terminal O4" "" {T0}
685 "signaling function, output terminal O5" "" {T0}
686 "signaling function, output terminal O6" "" {T0}
687 "signaling function, output terminal O7" "" {T0}
688 "signaling function, output terminal O8" "" {T0}
689 "signaling function, output terminal O9" "" {T0}
690 "signaling function, output terminal O10" "" {T0}
691 "signaling function, output terminal O11" "" {T0}
696 "Assignment, optional TERMINAL module outputs" "" {T0}
698 "Image of the output terminals" "" {T0}
698b0 "Signal state O0.x" "" {T0}
698b1 "Signal state O1.x" "" {T0}
698b2 "Signal state O2.x" "" {T0}
698b3 "Signal state O3.x" "" {T0}
698b4 "Signal status O4 (optional terminal module)" "" {T0}
698b5 "Signal status O5 (optional terminal module)" "" {T0}
698b6 "Signal status O6 (optional terminal module)" "" {T0}
698b7 "Signal status O7 (optional terminal module)" "" {T0}
698b8 "Signal status O8 (optional terminal module)" "" {T0}
698b9 "Signal status O9 (optional terminal module)" "" {T0}
698b10 "Signal status O10 (optional terminal module)" "" {T0}
698b11 "Signal status O11 (optional terminal module)" "" {T0}
699 "Inversion output terminal signals" "" {T0}
699b0 "Inverted: signal status O0.x" "" {T0}
699b1 "Inverted: signal status O1.x" "" {T0}
699b2 "Inverted: signal status O2.x" "" {T0}
699b3 "Inverted: signal status O3.x" "" {T0}
699b4 "Inverted: signal status O4 (optional terminal module)" "" {T0}
699b5 "Inverted: signal status O5 (optional terminal module)" "" {T0}
699b6 "Inverted: signal status O6 (optional terminal module)" "" {T0}
699b7 "Inverted: signal status O7 (optional terminal module)" "" {T0}
699b8 "Inverted: signal status O8 (optional terminal module)" "" {T0}
699b9 "Inverted: signal status O9 (optional terminal module)" "" {T0}
699b10 "Inverted: signal status O10 (optional terminal module)" "" {T0}
699b11 "Inverted: signal status O11 (optional terminal module)" "" {T0}
700 "Operating mode" "" {T0}
701 "Actual operating mode" "" {T0}
705 "Master Control" "" {T0}
706 "Sign-of-life Master Control" "" {T0}
709 "Control words via SimoCom U" "" {T0}
710 "Activate control words via SimoCom U" "" {T0}
711 "Input terminal signals via SimoCom U" "" {T0}
711b0 "SimoComU - input terminal signal I0.x" "" {T0}
711b1 "SimoComU - input terminal signal I1.x" "" {T0}
711b2 "SimoComU - input terminal signal I2.x" "" {T0}
711b3 "SimoComU - input terminal signal I3.x" "" {T0}
711b4 "SimoComU - input terminal signal I4" "" {T0}
711b5 "SimoComU - input terminal signal I5" "" {T0}
711b6 "SimoComU - input terminal signal I6" "" {T0}
711b7 "SimoComU - input terminal signal I7" "" {T0}
711b8 "SimoComU - input terminal signal I8" "" {T0}
711b9 "SimoComU - input terminal signal I9" "" {T0}
711b10 "SimoComU - input terminal signal I10" "" {T0}
711b11 "SimoComU - input terminal signal I11" "" {T0}
711b12 "SimoComU - controller enable at term. 65" "" {T0}
712 "Speed setpoint via SimoCom U" "Motor velocity setpoint via SimoCom U" {T0}
713 "Torque reduction via SimoCom U" "" {T0}
714 "Single block via SimoCom U: position" "" {T0}
715 "Single block via SimoCom U: velocity" "" {T0}
716 "Single block via SimoCom U: acceleration override" "" {T0}
717 "Single block via SimoCom U: deceleration override" "" {T0}
718 "Single block via SimoCom U: command" "" {T0}
719 "Single block via SimoCom U: command parameter" "" {T0}
720 "Single block via SimoCom U: mode" "" {T0}
730 "Saved parameters" "" {T0}
731 "Parameters required before start-up" "" {T0}
760 "Firmware download" "" {T0}
762 "Firmware download DP submodule" "" {T0}
801 "Changeover RS232/RS485" "" {T0}
802 "Drive number for RS485" "" {T0}
803 "Adjacent drive number" "" {T0}
820 "Fault end time" "" {T0}
821 "Time stamp, fault status change" "" {T0}
822 "Time stamp, warning status change" "" {T0}
823 "Fault number (active alarm)" "" {T0}
824 "Fault code (active alarm)" "" {T0}
825 "Fault time (active alarm)" "" {T0}
826 "Fault value (active alarm)" "" {T0}
827 "Acknowledge alarms" "" {T0}
828 "Warning value" "" {T0}
850 "Activate brake control" "" {T0}
851 "Brake release time" "" {T0}
852 "Speed, close holding brake" "Motor velocity, close holding brake" {T0}
853 "Brake delay time" "" {T0}
854 "Controller disable time" "" {T0}
868 "Baud rate selection, CAN bus" "" {T0}
870 "Module type" "" {T0}
871 "Module version" "" {T0}
872 "Option module type" "" {T0}
873 "Option module version" "" {T0}
874 "Drive position" "" {T0}
875 "Expected option module type" "" {T0}
879 "PROFIBUS configuration" "" {T0}
879b0 "Admissible sign-of-life error bit 0" "" {T0}
879b1 "Admissible sign-of-life error bit 1" "" {T0}
879b2 "Admissible sign-of-life error bit 2" "" {T0}
879b8 "Operation w/o sign-of-life monitor" "" {T0}
879b10 "Reserved" "" {T0}
879b11 "PKW processing: Subindex in the high byte" "" {T0}
879b12 "Activate direct measuring system" "" {T0}
879b13 "Incr. motor measuring sys.with/without equivalent zero mark" "" {T0}
879b14 "Incr. direct meas. system with/without equiv. zero mark" "" {T0}
879b15 "Reserved" "" {T0}
880 "Speed evaluation, PROFIBUS" "Motor velocity evaluation, PROFIBUS" {T0}
881 "Evaluation torque/power reduction PROFIBUS" "Evaluation force/power reduction PROFIBUS" {T0}
882 "Evaluation, torque setpont PROFIBUS" "Evaluation, force setpoint PROFIBUS" {T0}
883 "Override evaluation PROFIBUS" "" {T0}
884 "Position output evaluation PROFIBUS - number of increments" "" {T0}
888 "Function, distributed input (PROFIBUS)" "" {T0}
890 "Activate angular encoder/encoder interface" "" {T0}
891 "Source, external position reference value" "" {T0}
892 "No. of angular encoder marks / no. of encoder pulses factor" "" {T0}
893 "Angular encoder zero pulse offset" "" {T0}
894 "Angular encoder input signal waveform" "" {T0}
895 "External position reference value - number of increments" "" {T0}
896 "Ext. position ref. value - number of dimension system grids" "" {T0}
897 "Invert external position reference value" "" {T0}
898 "Modulo range master drive" "" {T0}
915 "PZD setpoint value assignment PROFIBUS" "" {T0}
916 "PZD actual value assignment PROFIBUS" "" {T0}
918 "PROFIBUS node address" "" {T0}
922 "PROFIBUS frame selection" "" {T0}
923 "List of PROFIBUS standard signals" "" {T0}
930 "PROFIBUS selector switch operating mode" "" {T0}
944 "Fault message counter" "" {T0}
945 "Fault code" "" {T0}
946 "Fault code list" "" {T0}
947 "Fault number" "" {T0}
948 "Fault time" "" {T0}
949 "Fault value" "" {T0}
951 "Fault number list" "" {T0}
952 "Number of faults" "" {T0}
953 "Warnings 800-815" "" {T0}
953b0 "800" "" {T0}
953b1 "801" "" {T0}
953b2 "802" "" {T0}
953b3 "803" "" {T0}
953b4 "804" "" {T0}
953b5 "805" "" {T0}
953b6 "806" "" {T0}
953b7 "807" "" {T0}
953b8 "808" "" {T0}
953b9 "809" "" {T0}
953b10 "810" "" {T0}
953b11 "811" "" {T0}
953b12 "812" "" {T0}
953b13 "813" "" {T0}
953b14 "814" "" {T0}
953b15 "815" "" {T0}
954 "Warnings 816-831" "" {T0}
954b0 "816" "" {T0}
954b1 "817" "" {T0}
954b2 "818" "" {T0}
954b3 "819" "" {T0}
954b4 "820" "" {T0}
954b5 "821" "" {T0}
954b6 "822" "" {T0}
954b7 "823" "" {T0}
954b8 "824" "" {T0}
954b9 "825" "" {T0}
954b10 "826" "" {T0}
954b11 "827" "" {T0}
954b12 "828" "" {T0}
954b13 "829" "" {T0}
954b14 "830" "" {T0}
954b15 "831" "" {T0}
955 "Warnings 832-847" "" {T0}
955b0 "832" "" {T0}
955b1 "833" "" {T0}
955b2 "834" "" {T0}
955b3 "835" "" {T0}
955b4 "836" "" {T0}
955b5 "837" "" {T0}
955b6 "838" "" {T0}
955b7 "839" "" {T0}
955b8 "840" "" {T0}
955b9 "841" "" {T0}
955b10 "842" "" {T0}
955b11 "843" "" {T0}
955b12 "844" "" {T0}
955b13 "845" "" {T0}
955b14 "846" "" {T0}
955b15 "847" "" {T0}
956 "Warnings 848-863" "" {T0}
956b0 "848" "" {T0}
956b1 "849" "" {T0}
956b2 "850" "" {T0}
956b3 "851" "" {T0}
956b4 "852" "" {T0}
956b5 "853" "" {T0}
956b6 "854" "" {T0}
956b7 "855" "" {T0}
956b8 "856" "" {T0}
956b9 "857" "" {T0}
956b10 "858" "" {T0}
956b11 "859" "" {T0}
956b12 "860" "" {T0}
956b13 "861" "" {T0}
956b14 "862" "" {T0}
956b15 "863" "" {T0}
957 "Warnings 864-879" "" {T0}
957b0 "864" "" {T0}
957b1 "865" "" {T0}
957b2 "866" "" {T0}
957b3 "867" "" {T0}
957b4 "868" "" {T0}
957b5 "869" "" {T0}
957b6 "870" "" {T0}
957b7 "871" "" {T0}
957b8 "872" "" {T0}
957b9 "873" "" {T0}
957b10 "874" "" {T0}
957b11 "875" "" {T0}
957b12 "876" "" {T0}
957b13 "877" "" {T0}
957b14 "878" "" {T0}
957b15 "879" "" {T0}
958 "Warnings 880-895" "" {T0}
958b0 "880" "" {T0}
958b1 "881" "" {T0}
958b2 "882" "" {T0}
958b3 "883" "" {T0}
958b4 "884" "" {T0}
958b5 "885" "" {T0}
958b6 "886" "" {T0}
958b7 "887" "" {T0}
958b8 "888" "" {T0}
958b9 "889" "" {T0}
958b10 "890" "" {T0}
958b11 "891" "" {T0}
958b12 "892" "" {T0}
958b13 "893" "" {T0}
958b14 "894" "" {T0}
958b15 "895" "" {T0}
959 "Warnings 896-911" "" {T0}
959b0 "896" "" {T0}
959b1 "897" "" {T0}
959b2 "898" "" {T0}
959b3 "899" "" {T0}
959b4 "900" "" {T0}
959b5 "901" "" {T0}
959b6 "902" "" {T0}
959b7 "903" "" {T0}
959b8 "904" "" {T0}
959b9 "905" "" {T0}
959b10 "906" "" {T0}
959b11 "907" "" {T0}
959b12 "908" "" {T0}
959b13 "909" "" {T0}
959b14 "910" "" {T0}
959b15 "911" "" {T0}
960 "Warnings 912-927" "" {T0}
960b0 "912" "" {T0}
960b1 "913" "" {T0}
960b2 "914" "" {T0}
960b3 "915" "" {T0}
960b4 "916" "" {T0}
960b5 "917" "" {T0}
960b6 "918" "" {T0}
960b7 "919" "" {T0}
960b8 "920" "" {T0}
960b9 "921" "" {T0}
960b10 "922" "" {T0}
960b11 "923" "" {T0}
960b12 "924" "" {T0}
960b13 "925" "" {T0}
960b14 "926" "" {T0}
960b15 "927" "" {T0}
963 "Baud rate PROFIBUS" "" {T0}
964 "Equipment identification" "" {T0}
965 "Profile number, PROFIdrive" "" {T0}
967 "PROFIBUS control word" "" {T0}
967b0 "ON / OFF1" "" {T0}
967b1 "Operating condition / OFF2" "" {T0}
967b2 "Operating condition / OFF3" "" {T0}
967b3 "Enable inverter/pulse inhibit" "" {T0}
967b4 "Ramp-fct.generator enable or OC/reject traversing task" "" {T0}
967b5 "Ramp-function generator start/stop or OC/intermed. stop" "" {T0}
967b6 "Enable setpoint and activate traversing task (edge)" "" {T0}
967b7 "Reset fault memory" "" {T0}
967b8 "Jog 1 ON / OFF" "" {T0}
967b9 "Jog 2 ON / OFF" "" {T0}
967b10 "Control requested / no control requested" "" {T0}
967b11 "Start referencing / exit referencing" "" {T0}
967b12 "Open the holding brake to test" "" {T0}
967b13 "Ramp-up time zero w. control.enable or ext. block change" "" {T0}
967b14 "Open-loop torque controlled operation" "" {T0}
967b15 "Spindle positioning on or request passive referencing" "" {T0}
968 "PROFIBUS status word" "" {T0}
968b0 "Ready to power-up / not ready to power-up" "" {T0}
968b1 "Ready to run or no fault" "" {T0}
968b2 "Status, controller enable" "" {T0}
968b3 "Fault available / no fault present" "" {T0}
968b4 "No OFF2 / OFF2 effective" "" {T0}
968b5 "No OFF3 / OFF3 effective" "" {T0}
968b6 "Power-on / No power-on inhibit" "" {T0}
968b7 "Alarm effective / No alarm present" "" {T0}
968b8 "n_set = n_act or no following error" "" {T0}
968b9 "Control requested" "" {T0}
968b10 "Comparison value reached or reference position reached" "" {T0}
968b11 "Reference point set / no reference point set" "" {T0}
968b12 "Setpoint acknowledge" "" {T0}
968b13 "Fct. generator active or drive is stationary / drive moving" "" {T0}
968b14 "Open-loop torque controlled operation" "" {T0}
968b15 "Spindle positioning on or request passive referencing" "" {T0}
969 "Current time difference" "" {T0}
972 "Request POWER-ON RESET" "" {T0}
979 "Encoder format" "" {T0}
979b0 " " "" {T0}
979b1 " " "" {T0}
979b2 " " "" {T0}
979b3 " " "" {T0}
979b4 " " "" {T0}
979b5 " " "" {T0}
979b6 " " "" {T0}
979b7 " " "" {T0}
979b8 " " "" {T0}
979b9 " " "" {T0}
979b10 " " "" {T0}
979b11 " " "" {T0}
979b12 " " "" {T0}
979b13 " " "" {T0}
979b14 " " "" {T0}
979b15 " " "" {T0}
979b16 " " "" {T0}
979b17 " " "" {T0}
979b18 " " "" {T0}
979b19 " " "" {T0}
979b20 " " "" {T0}
979b21 " " "" {T0}
979b22 " " "" {T0}
979b23 " " "" {T0}
979b24 " " "" {T0}
979b25 " " "" {T0}
979b26 " " "" {T0}
979b27 " " "" {T0}
979b28 " " "" {T0}
979b29 " " "" {T0}
979b30 " " "" {T0}
979b31 " " "" {T0}
980 "Number list_1" "" {T0}
981 "Number list_2" "" {T0}
982 "Number list_3" "" {T0}
983 "Number list_4" "" {T0}
984 "Number list_5" "" {T0}
985 "Number list_6" "" {T0}
986 "Number list_7" "" {T0}
987 "Number list_8" "" {T0}
988 "Number list_9" "" {T0}
989 "Number list_10" "" {T0}
1000 "Current controller cycle" "" {T0}
1001 "Speed controller cycle" "" {T0}
1003 "STS configuration" "" {T0}
1003b4 "Supersine" "" {T0}
1003b5 "Masking pulse suppression" "" {T0}
1003b6 "Time base TBSYN" "" {T0}
1003b7 "Time base ATD" "" {T0}
1003b8 "SYNO synchronization" "" {T0}
1003b9 "Time base EX_TBYN" "" {T0}
1003b10 "STROBE -> XINT division ratio" "" {T0}
1004 "Structure configuration" "" {T0}
1004b4 "Integrator control" "" {T0}
1004b8 "Fine interpolation in positioning mode" "" {T0}
1004b9 "Dead time calibr., pos. ref. value coupling via Profibus DP" "" {T0}
1005 "IM encoder pulse number" "" {T0}
1006 "IM encoder code number" "" {T0}
1007 "DM encoder pulse number" "" {T0}
1008 "IM encoder phase error correction" "" {T0}
1009 "Position controller cycle" "" {T0}
1010 "Interpolation cycle" "" {T0}
1011 "IM configuration, actual value sensing" "" {T0}
1011b0 "Inversion, speed actual value" "" {T0}
1011b1 "Encoder phase error compensation" "" {T0}
1011b2 "Resolver resolution" "" {T0}
1011b12 "Identify coarse position" "" {T0}
1011b13 "Identify fine position" "" {T0}
1011b14 "EnDat transmission rate, bit 0 (LSB)" "" {T0}
1011b15 "EnDat transmission rate, bit 1" "" {T0}
1012 "Function switch" "" {T0}
1012b0 "Ramp-function generator follow-up" "" {T0}
1012b2 "Ready (terminal-dependent) / no fault" "" {T0}
1012b4 "Reserved" "" {T0}
1012b5 "Suppress fault 753" "" {T0}
1012b7 "Induction motor speed actual value after pulse inhibit" "" {T0}
1012b8 "Average value filter, speed setpoint" "" {T0}
1012b12 "Power-on inhibit for alarm and OFF2/OFF3" "" {T0}
1012b13 "Power-on inhibit according to the PROFIdrive profile" "" {T0}
1012b14 "No power-on inhib. if all enab. signals are simult. entered" "" {T0}
1013 "Enable motor changeover" "" {T0}
1014 "Activate V/f operation" "" {T0}
1015 "Activate PE-MSD" "" {T0}
1016 "Commutation angle offset" "" {T0}
1017 "Start-up support" "" {T0}
1018 "IM pole pair number, resolver" "" {T0}
1019 "Current, rotor position ID" "" {T0}
1020 "Maximum rotation, rotor position identification" "Maximum movement, rotor position identification" {T0}
1021 "IM multi-turn resolution, absolute value encoder" "" {T0}
1022 "IM single-turn resolution, absolute value encoder" "" {T0}
1023 "IM diagnostics" "" {T0}
1023b0 "Lighting failure" "" {T0}
1023b1 "Signal amplitude too low" "" {T0}
1023b2 "Faulty code connection" "" {T0}
1023b3 "Overvoltage" "" {T0}
1023b4 "Undervoltage" "" {T0}
1023b5 "Overcurrent" "" {T0}
1023b6 "Fresh battery required" "" {T0}
1023b7 "Check error" "" {T0}
1023b8 "EnDat encoder cannot be used" "" {T0}
1023b9 "CD track defective on ERN1387" "" {T0}
1023b10 "Log cannot be aborted" "" {T0}
1023b11 "" ; "SSI signal level incorrect" "" {T0}
1023b12 "TIMEOUT on reading measured value" "" {T0}
1023b13 "CRC error or parity error" "" {T0}
1023b14 "" ; "SSI encoder signals an alarm" "" {T0}
1023b15 "Encoder defective" "" {T0}
1024 "IM Grid spacing" "" {T0}
1025 "IM serial number, low part" "" {T0}
1026 "IM serial number, high part" "" {T0}
1027 "IM configuration, encoder" "" {T0}
1027b2 "TTL encoder" "" {T0}
1027b3 "Absolute encoder (EnDat interface)" "" {T0}
1027b4 "Linear measuring system" "" {T0}
1027b5 "Operation without motor measuring system" "" {T0}
1027b6 "Rough synchronizing track, el. revolution" "" {T0}
1027b7 "Distance-coded measuring system" "" {T0}
1027b8 "Zero mark selection, fine sync using position controller" "" {T0}
1027b9 "Reserved for Posmo. Implementation missing" "" {T0}
1027b10 "" ; "SSI encoder: Binary code/gray code" "" {T0}
1027b11 "" ; "SSI encoder: Hierarchical/right-justified format" "" {T0}
1027b12 "" ; "SSI encoder: Parity bit active" "" {T0}
1027b13 "" ; "SSI encoder: Parity bit even/odd" "" {T0}
1027b14 "" ; "SSI encoder: Alarm bit active" "" {T0}
1027b15 "" ; "SSI encoder active" "" {T0}
1028 "IM telegram length SSI" "" {T0}
1029 "Delayed measurement, rotor position identification" "" {T0}
1030 "DM actual value sensing configuration" "" {T0}
1030b2 "Resolver resolution" "" {T0}
1030b14 "EnDat transmission rate, bit 0 (LSB)" "" {T0}
1030b15 "EnDat transmission rate, bit 1" "" {T0}
1031 "DM multi-turn resolution, absolute value encoder" "" {T0}
1032 "DM single-turn resolution, absolute value encoder" "" {T0}
1033 "DM diagnostics" "" {T0}
1033b0 "Lighting failure" "" {T0}
1033b1 "Signal amplitude too low" "" {T0}
1033b2 "Faulty code connection" "" {T0}
1033b3 "Overvoltage" "" {T0}
1033b4 "Undervoltage" "" {T0}
1033b5 "Overcurrent" "" {T0}
1033b6 "Fresh battery required" "" {T0}
1033b7 "Check error" "" {T0}
1033b8 "EnDat encoder cannot be used" "" {T0}
1033b9 "CD track defective on ERN1387" "" {T0}
1033b10 "Log cannot be aborted" "" {T0}
1033b11 "" ; "SSI signal level incorrect" "" {T0}
1033b12 "TIMEOUT on reading measured value" "" {T0}
1033b13 "CRC error or parity error" "" {T0}
1033b14 "" ; "SSI encoder signals an alarm" "" {T0}
1033b15 "Encoder defective" "" {T0}
1034 "DM grid spacing" "" {T0}
1036 "DM encoder code number" "" {T0}
1037 "DM encoder configuration" "" {T0}
1037b2 "TTL encoder" "" {T0}
1037b3 "Absolute encoder (EnDat interface)" "" {T0}
1037b4 "Linear measuring system" "" {T0}
1037b5 "Operation without direct measuring system" "" {T0}
1037b7 "Distance-coded measuring system" "" {T0}
1037b9 "Reserved for Posmo. Implementation missing" "" {T0}
1037b10 "" ; "SSI encoder: Binary code/gray code" "" {T0}
1037b11 "" ; "SSI encoder: Hierarchical/right-justified format" "" {T0}
1037b12 "" ; "SSI encoder: Parity bit active" "" {T0}
1037b13 "" ; "SSI encoder: Parity bit even/odd" "" {T0}
1037b14 "" ; "SSI encoder: Alarm bit active" "" {T0}
1037b15 "" ; "SSI encoder active" "" {T0}
1038 "DM serial number, low part" "" {T0}
1039 "DM serial number, high part" "" {T0}
1040 "DM pole pair number, resolver" "" {T0}
1041 "DM telegram length SSI" "" {T0}
1042 "Encoder 1 fine resolution G1_XIST1" "" {T0}
1043 "Encoder 1 fine resolution, absolute track G1_XIST2" "" {T0}
1044 "Encoder 2 fine resolution G2_XIST1" "" {T0}
1045 "Encoder 2 fine resolution, absolute track G2_XIST2" "" {T0}
1050 "IM reference mark clearance for distance-coded scales" "" {T0}
1051 "IM ref. mark clearance for distance-coded rotary encoders" "" {T0}
1052 "DM reference mark distance for distance-coded scales" "" {T0}
1053 "DM ref. mark distance for distance-coded rotary encoders" "" {T0}
1075 "Rotor position identification technique" "" {T0}
1076 "Load moment of inertia RLI" "Load mass RLI" {T0}
1077 "Integral action time, RLI controller" "" {T0}
1078 "Max. duration, rotor position identification." "" {T0}
1080 "Calculate controller data" "" {T0}
1081 "Calculate equivalent circuit diagram data" "" {T0}
1082 "Calculate third-party motor" "" {T0}
1083 "Function selection, motor data optimization" "" {T0}
1084 "Start motor data optimization" "" {T0}
1099 "Limiting factor, power section currents" "" {T0}
1100 "Pulse width modulation frequency" "" {T0}
1101 "Calc. deadtime current control loop" "" {T0}
1102 "Motor code number" "" {T0}
1103 "Rated motor current" "" {T0}
1104 "Maximum motor current" "" {T0}
1105 "Reduction in maximum motor current" "" {T0}
1106 "Power section code number" "" {T0}
1107 "Transistor limiting current" "" {T0}
1108 "Limiting current, power section (RMS)" "" {T0}
1109 "Limiting current, power section S6 (RMS)" "" {T0}
1110 "Power section version" "" {T0}
1111 "Rated current, power section (RMS)" "" {T0}
1112 "No. of pole pairs of motor" "" {T0}
1113 "Torque constant" "Force constant" {T0}
1114 "Voltage constant" "" {T0}
1115 "Armature resistance" "" {T0}
1116 "Armature inductance" "" {T0}
1117 "Moment of inertia of motor" "Motor mass" {T0}
1118 "Motor zero-speed current" "" {T0}
1119 "Series reactor inductance" "" {T0}
1120 "Current controller P gain" "" {T0}
1121 "Current controller reset time" "" {T0}
1122 "Motor current limit" "" {T0}
1123 "Load moment of inertia" "Load weight" {T0}
1124 "Symmetrizing reference model current" "" {T0}
1125 "Ramp-up time 1 for V/f operation" "" {T0}
1126 "Ramp-up time 2 for V/f operation" "" {T0}
1127 "Voltage at f = 0 V/f operation" "" {T0}
1128 "Optimum load angle" "" {T0}
1129 "Cosine Phi power factor" "" {T0}
1130 "Rated motor power" "" {T0}
1132 "Rated motor voltage" "" {T0}
1134 "Rated motor frequency" "" {T0}
1135 "Motor no-load voltage" "" {T0}
1136 "Motor no-load current" "" {T0}
1137 "Stator resistance cold" "" {T0}
1138 "Rotor resistance cold" "" {T0}
1139 "Stator leakage reactance" "" {T0}
1140 "Rotor leakage reactance" "" {T0}
1141 "Magnetizing reactance" "" {T0}
1142 "Threshold speed field weakening" "Motor threshold speed for field weakening" {T0}
1143 "Upper speed Lh characteristic" "" {T0}
1144 "Amplification factor Lh characteristic" "" {T0}
1145 "Stall torque reduction factor" "" {T0}
1146 "Maximum motor speed" "Maximum motor velocity" {T0}
1147 "Speed limitation" "Velocity limiting, motor" {T0}
1148 "Threshold speed stall power" "" {T0}
1149 "Reluctance torque constant" "" {T0}
1150 "P-gain flux controller" "" {T0}
1151 "Reset time flux controller" "" {T0}
1160 "Threshold speed flux sensing" "" {T0}
1161 "Fixed DC link voltage" "" {T0}
1162 "Min. DC link voltage" "" {T0}
1163 "Max. DC link voltage" "" {T0}
1170 "Pole pair width" "" {T0}
1171 "Line supply voltage 480 V" "" {T0}
1173 "Highest load time, power module" "" {T0}
1174 "Pulse cancellation time, power module" "" {T0}
1175 "Synchr. reduction factor for P1108" "" {T0}
1176 "Synchr. reduction factor for P1109" "" {T0}
1177 "Synchr. reduction factor for P1111" "" {T0}
1178 "Synchr. current reduction factor" "" {T0}
1179 "Asynchr. current reduction factor" "" {T0}
1180 "Lower current limit adaption" "" {T0}
1181 "Upper current limit adaption" "" {T0}
1182 "Factor, current controller adaption" "" {T0}
1185 "Start-up factor P_IREG" "" {T0}
1200 "No. of current setpoint filters" "" {T0}
1201 "Current setpoint filter type" "" {T0}
1201b0 "1st filter: 0=lowpass / 1=bandstop" "" {T0}
1201b1 "2nd filter: 0=lowpass / 1=bandstop" "" {T0}
1201b2 "3rd filter: 0=lowpass / 1=bandstop" "" {T0}
1201b3 "4th filter: 0=lowpass / 1=bandstop" "" {T0}
1201b15 "new bandstop filters: 0=old / 1=new" "" {T0}
1202 "Natural frequency current setp. filter 1" "" {T0}
1203 "Damping, current setp. filter 1" "" {T0}
1204 "Natural frequency current setp. filter 2" "" {T0}
1205 "Damping, current setp. filter 2" "" {T0}
1206 "Natural frequency current setp. filter 3" "" {T0}
1207 "Damping, current setp. filter 3" "" {T0}
1208 "Natural frequency current setp. filter 4" "" {T0}
1209 "Damping, current setp. filter 4" "" {T0}
1210 "Blocking freq. current setp. filter 1" "" {T0}
1211 "Bandwidth, current setp. filter 1" "" {T0}
1212 "Numerator, bandwidth current setpoint filter 1" "" {T0}
1213 "Blocking freq. current setp. filter 2" "" {T0}
1214 "Bandwidth, current setp. filter 2" "" {T0}
1215 "Numerator, bandwidth current setpoint filter 2" "" {T0}
1216 "Blocking freq. current setp. filter 3" "" {T0}
1217 "Bandwidth, current setp. filter 3" "" {T0}
1218 "Numerator, bandwidth current setpoint filter 3" "" {T0}
1219 "Blocking freq. current setp. filter 4" "" {T0}
1220 "Bandwidth, current setp. filter 4" "" {T0}
1221 "Numerator, bandwidth current setpoint filter 4" "" {T0}
1222 "BSF natural frequency, current setpoint filter 1" "" {T0}
1223 "BSF natural frequency, current setpoint filter 2" "" {T0}
1224 "BSF natural frequency, current setpoint filter 3" "" {T0}
1225 "BSF natural frequency, current setpoint filter 4" "" {T0}
1230 "1st torque limit value" "1st force limit value" {T0}
1233 "Generative limitation" "" {T0}
1235 "1st power limit" "" {T0}
1237 "Maximum generative power" "" {T0}
1238 "Current limit value" "" {T0}
1240 "Torque setpoint offset (speed-contr.)" "Force setpoint offset (speed-contr.)" {T0}
1241 "Normalization of torque setpoint" "Normalization of force setpoint" {T0}
1242 "Torque setpoint offset (torque-contr.)" "Offset, force setpoint (torque-controlled)" {T0}
1243 "Normalization, torque/power reduction." "Normalization, force/power reduction." {T0}
1244 "Characteristic type, torque/power reduction" "Characteristic type, force/power reduction" {T0}
1245 "Threshold, speeddependent M_set smoothing" "Threshold, velocity-dependent F_set smoothing" {T0}
1246 "Hysteresis, speeddependent M_set smoothing" "Hysteresis, velocity-dependent F_set smoothing" {T0}
1247 "Speed threshold, motor changeover 1 / 2" "" {T0}
1248 "Speed threshold, motor changeover 3 / 4" "" {T0}
1249 "External contactor control, motor changeover" "" {T0}
1250 "Frequency limit, act. current smoothing" "" {T0}
1251 "Time constant (smoothing) motor utilization" "" {T0}
1252 "Frequency limit, torque setpoint smoothing" "Frequency limit, force setpoint smoothing" {T0}
1254 "Time constant current monitoring" "" {T0}
1256 "Ramp-function generator ramp-up time" "" {T0}
1257 "Ramp-function generator ramp-down time" "" {T0}
1259 "Torque/power reduction mot./gen." "Force/power reduction mot./gen." {T0}
1260 "i2t limiting, limit current, power section S6" "" {T0}
1261 "i2t limiting, rated current power section current" "" {T0}
1262 "i2t time in limiting" "" {T0}
1263 "i2t actual limiting factor" "" {T0}
1264 "i2t actual utilization factor" "" {T0}
1267 "Pulsed resistor: Actual utilization factor" "" {T0}
1400 "Rated motor speed" "Rated motor velocity" {T0}
1401 "Speed for max. useful motor speed" "Velocity for max. useful motor velocity" {T0}
1403 "Creep speed pulse suppression" "creep speed, pulse suppression" {T0}
1404 "Timer pulse suppression" "" {T0}
1405 "Monitoring speed, motor" "Monitoring velocity, motor" {T0}
1407 "Speed controller P gain" "Velocity controller P gain" {T0}
1408 "P gain, upper adaption speed" "P gain, upper adaption velocity" {T0}
1409 "Speed controller reset time" "Velocity controller reset time" {T0}
1410 "Integral action time, upper adaption speed" "Integral action time, upper adaption velocity" {T0}
1411 "Lower adaptation speed" "Lower adaption velocity, motor" {T0}
1412 "Upper adaptation speed" "Upper adaption speed, motor" {T0}
1413 "Select speed controller adaptation" "Select velocity control adaption" {T0}
1414 "Natural frequency, reference model speed" "Natural frequency, reference model velocity" {T0}
1415 "Damping, reference model speed" "Damping, reference model velocity" {T0}
1416 "Balancing, reference model, speed" "Balancing, reference model, velocity" {T0}
1417 "n_x for 'n_act < n_x' signal" "" {T0}
1418 "n_min for 'n_act < n_min' signal" "" {T0}
1421 "Time constant, integrator feedback (n controller)" "" {T0}
1426 "Toler.bandwidth f.'n_set = n_act' signal" "" {T0}
1427 "Delay time 'n_set = n_act' signal" "" {T0}
1428 "Threshold torque M_x" "Threshold force F_x" {T0}
1429 "Delay time 'M < M_x' signal" "Delay time 'F < F_x' signal" {T0}
1451 "P gain speed controller AM" "" {T0}
1453 "Reset time speed controller AM" "" {T0}
1458 "Current setpoint, controlled range IM" "" {T0}
1459 "Torque smoothing time constant IM" "" {T0}
1465 "Switching speed MSD/AM" "" {T0}
1466 "Changeover speed, open-loop/closed-loop control IM" "" {T0}
1500 "No. of speed setpoint filters" "No. of velocity setpoint filters" {T0}
1501 "Type of speed setpoint filter" "Type of velocity setpoint filter" {T0}
1501b0 "1st filter: 0=lowpass / 1=bandstop" "" {T0}
1501b1 "2nd filter: 0=lowpass / 1=bandstop" "" {T0}
1501b8 "1st filter: 0=PT2 / 1=PT1 with lowpass" "" {T0}
1501b9 "2nd filter: 0=PT2 / 1=PT1 with lowpass" "" {T0}
1501b15 "new bandstop filters: 0=old / 1=new" "" {T0}
1502 "Time constant, speed setpoint filter 1" "Time constant, velocity setpoint filter 1" {T0}
1503 "Time constant, speed setpoint filter 2" "Time constant, velocity setpoint filter 2" {T0}
1506 "Natural frequency, speed setpoint filter 1" "Natural frequency, velocity setpoint filter 1" {T0}
1507 "Damping, speed setpoint filter 1" "Damping, velocity setpoint filter 1" {T0}
1508 "Natural frequency, speed setpoint filter 2" "Natural frequency, velocity setpoint filter 2" {T0}
1509 "Damping, speed setpoint filter 2" "Damping, velocity setpoint filter 2" {T0}
1514 "Blocking frequency, speed setpoint filter 1" "Blocking frequency, velocity setpoint filter 1" {T0}
1515 "Bandwidth, speed setpoint filter 1" "Bandwidth, velocity setpoint filter 1" {T0}
1516 "Numerator, bandwidth speed setpoint filter 1" "Numerator, bandwidth velocity setpoint filter 1" {T0}
1517 "Blocking frequency, speed setpoint filter 2" "Blocking frequency, velocity setpoint filter 2" {T0}
1518 "Bandwidth, speed setpoint filter 2" "Bandwidth, velocity setpoint filter 2" {T0}
1519 "Numerator, bandwidth speed setpoint filter 2" "Numerator, bandwidth velocity setpoint filter 2" {T0}
1520 "BSP natural frequency, speed setpoint filter 1" "BSF natural frequency velocity setpoint filter 1" {T0}
1521 "BSP natural frequency, speed setpoint filter 2" "BSP natural frequency, velocity setpoint filter 2" {T0}
1522 "Time constant, speed actual value filter (PT1)" "Time constant, velocity actual value filter (PT1)" {T0}
1600 "Suppressible faults 1" "" {T0}
1600b4 "Meas. circ. motor meas. system" "" {T0}
1600b5 "Absolute track monitoring" "" {T0}
1600b7 "Synchronization error rotor position" "" {T0}
1600b8 "Zero mark monitoring, motor measuring system" "" {T0}
1600b9 "Converter limit frequency too high" "" {T0}
1600b12 "Measuring circuit, direct measuring system" "" {T0}
1600b13 "Monitoring, absolute track dir. measuring system" "" {T0}
1600b14 "Zero mark monitoring, direct measuring system" "" {T0}
1600b17 "Hardware defect, terminal pulse enable" "" {T0}
1601 "Suppressible faults 2" "" {T0}
1601b1 "Error in A/D conversion Trm.56/14 or Trm.24/20" "" {T0}
1601b5 "Position controller output limited" "" {T0}
1601b6 "Flux controller at stop" "" {T0}
1601b7 "Current controller at stop" "" {T0}
1601b8 "Speed controller at stop" "" {T0}
1601b9 "Encoder limit frequency exceeded" "" {T0}
1601b13 "Motor temperature: shutdown limit (P1607) exceeded" "" {T0}
1601b14 "Delayed shutdown for motor overtemp. (P1602/P1603)" "" {T0}
1601b15 "DM encoder limiting frequency exceeded" "" {T0}
1601b18 "Sum of the phase currents not equal to zero" "" {T0}
1601b19 "Measuring circuit error absolute current (hardware)" "" {T0}
1601b20 "24V electronics power supply too low" "" {T0}
1601b21 "24V electronics power supply too high" "" {T0}
1601b22 "Motor holding brake defective" "" {T0}
1601b23 "Brake sequence control inactive" "" {T0}
1602 "Alarm threshold, motor overtemperature" "" {T0}
1603 "Motor temperature alarm timer" "" {T0}
1604 "DC link undervoltage warning threshold" "" {T0}
1605 "Timer n controller at stop" "" {T0}
1606 "Threshold n controller at stop" "" {T0}
1607 "Shutdown limit motor temperature" "" {T0}
1608 "Fixed temperature" "" {T0}
1610 "Diagnostic functions" "" {T0}
1610b0 "dn/dt monitoring" "" {T0}
1610b1 "Rotational accuracy monitor" "" {T0}
1611 "Response threshold dn/dt" "" {T0}
1612 "Shutdown response, faults 1" "" {T0}
1612b1 "Measuring circuit error, absolute current" "" {T0}
1612b4 "Meas. circ. motor meas. system" "" {T0}
1612b5 "Absolute track monitoring" "" {T0}
1612b7 "Synchronization error rotor position" "" {T0}
1612b8 "Zero mark monitoring, motor measuring system" "" {T0}
1612b9 "Converter limit frequency too high" "" {T0}
1612b12 "Measuring circuit, direct measuring system" "" {T0}
1612b13 "Monitoring, absolute track dir. measuring system" "" {T0}
1612b14 "Zero mark monitoring, direct measuring system" "" {T0}
1612b15 "Heatsink temperature exceeded" "" {T0}
1612b16 "Electronics temperature exceeded" "" {T0}
1612b17 "Hardware defect, terminal pulse enable" "" {T0}
1613 "Shutdown response, faults 2" "" {T0}
1613b1 "Error in A/D conversion Trm.56/14 or Trm.24/20" "" {T0}
1613b2 "Open-loop torque controlled oper. w/o encoder is not perm." "" {T0}
1613b3 "Changeover to non-parameterized motor data set" "" {T0}
1613b5 "Position controller output limited" "" {T0}
1613b6 "Flux controller at stop" "" {T0}
1613b7 "Current controller at stop" "" {T0}
1613b8 "Speed controller at stop" "" {T0}
1613b9 "Encoder limit frequency exceeded" "" {T0}
1613b10 "Rotor position identification has failed" "" {T0}
1613b11 "Illegal motion during rotor position identification" "" {T0}
1613b12 "Illegal current during rotor position identification" "" {T0}
1613b13 "Motor temperature: shutdown limit (P1607) exceeded" "" {T0}
1613b14 "Delayed shutdown for motor overtemp. (P1602/P1603)" "" {T0}
1613b15 "DM encoder limiting frequency exceeded" "" {T0}
1613b16 "DC link undervoltage" "" {T0}
1613b17 "DC link overvoltage" "" {T0}
1613b18 "Sum of the phase currents not equal to zero" "" {T0}
1613b19 "Measuring circuit error absolute current (hardware)" "" {T0}
1613b20 "24V electronics power supply too low" "" {T0}
1613b21 "24V electronics power supply too high" "" {T0}
1615 "Tolerance rotational accuracy monitor" "" {T0}
1616 "Diagnosis, actual speed value" "" {T0}
1618 "Test functions 1" "" {T0}
1619 "Test functions 2" "" {T0}
1620 "Bits for variable signaling function" "" {T0}
1620b0 "Variable signaling function" "" {T0}
1620b1 "Segment variable signaling function" "" {T0}
1620b2 "Comparison with sign" "" {T0}
1621 "Signal number, variable signaling function" "" {T0}
1622 "Address, variable signaling function" "" {T0}
1623 "Threshold, variable signaling function" "" {T0}
1624 "Hysteresis, variable signaling function" "" {T0}
1625 "Pull-in delay, variable signaling function" "" {T0}
1626 "Drop-out delay, variable signaling function" "" {T0}
1630 "Response threshold, DC link monitoring" "" {T0}
1631 "Response threshold generator axis" "" {T0}
1632 "Voltage step for generator control" "" {T0}
1633 "Cutoff threshold for generator mode" "" {T0}
1634 "Response threshold emergency retraction" "" {T0}
1635 "Minimum speed generator axis" "Minimum velocity generator axis" {T0}
1636 "Mode, emergency retraction/regenerative operation" "" {T0}
1637 "Deceleration time, regenerative braking" "" {T0}
1638 "Emergency retraction time" "" {T0}
1639 "Emergency retraction speed" "Emergency retraction velocity, motor" {T0}
1640 "Armature short-circuit, fault 1" "" {T0}
1640b1 "Measuring circuit error, absolute current" "" {T0}
1640b4 "Meas. circ. motor meas. system" "" {T0}
1640b5 "Absolute track monitoring" "" {T0}
1640b7 "Synchronization error rotor position" "" {T0}
1640b8 "Zero mark monitoring, motor measuring system" "" {T0}
1640b9 "Converter limit frequency too high" "" {T0}
1640b12 "Measuring circuit, direct measuring system" "" {T0}
1640b13 "Absolute track monitoring" "" {T0}
1640b14 "Zero mark monitoring, direct measuring system" "" {T0}
1640b15 "Heatsink temperature exceeded" "" {T0}
1640b16 "Electronics temperature exceeded" "" {T0}
1640b17 "Hardware defect, terminal pulse enable" "" {T0}
1641 "Armature short-circuit, fault 2" "" {T0}
1641b2 "Open-loop torque controlled oper. w/o encoder is not perm." "" {T0}
1641b3 "Changeover to non-parameterized motor data set" "" {T0}
1641b5 "Position controller output limited" "" {T0}
1641b6 "Flux controller at stop" "" {T0}
1641b7 "Current controller at stop" "" {T0}
1641b8 "Speed controller at stop" "" {T0}
1641b9 "Encoder limit frequency exceeded" "" {T0}
1641b10 "Rotor position identification has failed" "" {T0}
1641b11 "Illegal motion during rotor position identification" "" {T0}
1641b12 "Illegal current during rotor position identification" "" {T0}
1641b13 "Motor temperature: shutdown limit (P1607) exceeded" "" {T0}
1641b14 "Delayed shutdown for motor overtemp. (P1602/P1603)" "" {T0}
1641b15 "DM encoder limiting frequency exceeded" "" {T0}
1641b16 "DC link undervoltage" "" {T0}
1641b17 "DC link overvoltage" "" {T0}
1641b18 "Sum of the phase currents not equal to zero" "" {T0}
1641b19 "Measuring circuit error absolute current (hardware)" "" {T0}
1641b20 "24V electronics power supply too low" "" {T0}
1641b21 "24V electronics power supply too high" "" {T0}
1642 "Shutdown response, various faults" "" {T0}
1642b0 "NMI due to Watchdog" "" {T0}
1650 "Diagnostics control" "" {T0}
1650b0 "Min/Max memory" "" {T0}
1650b1 "Min/Max memory segment" "" {T0}
1650b2 "Comparison with sign" "" {T0}
1650b15 "Cycl. display of parameter number" "" {T0}
1651 "Signal number, min/max memory" "" {T0}
1652 "Memory location min/max memory" "" {T0}
1653 "Minimum value Min/Max memory" "" {T0}
1654 "Maximum value Min/Max memory" "" {T0}
1655 "Segment memory location monitor" "" {T0}
1656 "Address memory location monitor" "" {T0}
1657 "Value display monitor" "" {T0}
1657b0 " " "" {T0}
1657b1 " " "" {T0}
1657b2 " " "" {T0}
1657b3 " " "" {T0}
1657b4 " " "" {T0}
1657b5 " " "" {T0}
1657b6 " " "" {T0}
1657b7 " " "" {T0}
1657b8 " " "" {T0}
1657b9 " " "" {T0}
1657b10 " " "" {T0}
1657b11 " " "" {T0}
1657b12 " " "" {T0}
1657b13 " " "" {T0}
1657b14 " " "" {T0}
1657b15 " " "" {T0}
1657b16 " " "" {T0}
1657b17 " " "" {T0}
1657b18 " " "" {T0}
1657b19 " " "" {T0}
1657b20 " " "" {T0}
1657b21 " " "" {T0}
1657b22 " " "" {T0}
1657b23 " " "" {T0}
1658 "Value input monitor" "" {T0}
1658b0 " " "" {T0}
1658b1 " " "" {T0}
1658b2 " " "" {T0}
1658b3 " " "" {T0}
1658b4 " " "" {T0}
1658b5 " " "" {T0}
1658b6 " " "" {T0}
1658b7 " " "" {T0}
1658b8 " " "" {T0}
1658b9 " " "" {T0}
1658b10 " " "" {T0}
1658b11 " " "" {T0}
1658b12 " " "" {T0}
1658b13 " " "" {T0}
1658b14 " " "" {T0}
1658b15 " " "" {T0}
1658b16 " " "" {T0}
1658b17 " " "" {T0}
1658b18 " " "" {T0}
1658b19 " " "" {T0}
1658b20 " " "" {T0}
1658b21 " " "" {T0}
1658b22 " " "" {T0}
1658b23 " " "" {T0}
1659 "Value acceptance monitor" "" {T0}
1701 "DC link voltage" "" {T0}
1702 "Motor temperature 840D" "" {T0}
1703 "Lead time, motor measuring system conversion" "" {T0}
1704 "Lead time, conversion direct measuring system" "" {T0}
1705 "Voltage setpoint (rms)" "" {T0}
1706 "Motor speed setpoint 840D" "Velocity setpoint, motor 840D" {T0}
1707 "Actual motor speed 840D" "Velocity actual value, motor 840D" {T0}
1708 "Torque generating current Iq" "" {T0}
1709 "Significance, voltage representation" "" {T0}
1710 "Significance, current representation" "" {T0}
1711 "Significance, speed representation" "Significance, velocity representation" {T0}
1712 "Significance, rotor flux representation" "" {T0}
1713 "Significance torque representation" "Significance, force representation" {T0}
1716 "Torque setpoint" "Force setpoint" {T0}
1717 "Limiting factor for torque/power" "Limiting factor for force/power" {T0}
1718 "Torque-generating current Iq (A)" "" {T0}
1719 "Actual absolute current (rms)" "" {T0}
1723 "Diagnosis, ramp-up time" "" {T0}
1724 "Diagnosis, rotational accuracy monitor" "" {T0}
1725 "Normalization of torque setpoint" "Normalization of force setpoint" {T0}
1726 "Calculated jerk time" "" {T0}
1727 "Status display for SimoCom U" "" {T0}
1727b0 "Possible to activate direct measuring system" "" {T0}
1727b1 "TTL encoder as direct measuring system" "" {T0}
1729 "Actual rotor position (electrical)" "" {T0}
1731 "Image ZK1_PO register" "" {T0}
1731b1 "Monitoring current space vector" "" {T0}
1731b4 "Meas. circ. motor meas. system" "" {T0}
1731b5 "Absolute track monitoring" "" {T0}
1731b7 "Synchronization error rotor position" "" {T0}
1731b8 "Zero mark monitoring, motor measuring system" "" {T0}
1731b9 "Converter limit frequency too high" "" {T0}
1731b10 "Error in center frequency measurement" "" {T0}
1731b11 "Measured value memory active" "" {T0}
1731b15 "Temperature monitoring power section" "" {T0}
1732 "Image ZK1_RES register" "" {T0}
1732b1 "Error in A/D conversion Trm.56/14 or Trm.24/20" "" {T0}
1732b2 "Open-loop torque controlled oper. w/o encoder is not perm." "" {T0}
1732b3 "Changeover to non-parameterized motor data set" "" {T0}
1732b5 "Position controller output limited" "" {T0}
1732b6 "Flux controller at stop" "" {T0}
1732b7 "Current controller at stop" "" {T0}
1732b8 "Speed controller at stop" "" {T0}
1732b9 "Encoder limit frequency exceeded" "" {T0}
1732b10 "Rotor position identification has failed" "" {T0}
1732b11 "Inadmissible movement for rotor position identification" "" {T0}
1732b12 "Inadmissible current for rotor position identification" "" {T0}
1732b13 "Shutdown limit, motor overtemperature (P1607) exceeded" "" {T0}
1732b14 "Alarm threshold, motor overtemp. (P1602/P1603) exceeded" "" {T0}
1732b16 "DC link undervoltage" "" {T0}
1732b17 "DC link overvoltage" "" {T0}
1732b18 "Sum of the phase currents not equal to zero" "" {T0}
1733 "NPFK diagnosis counter" "" {T0}
1734 "Diagnostics, rotor position identification" "" {T0}
1735 "Processor utilization" "" {T0}
1736 "Test, rotor position identification" "" {T0}
1737 "Difference, rotor position identification" "" {T0}
1738 "No. of data backup operations in the FEPROM" "" {T0}
1739 "You must save in the FEPROM" "" {T0}
1740 "Significance, abs. speed act. value representation (fine)" "Significance, abs.velocity act.value representation(fine)" {T0}
1741 "Significance, utilization representation (fine)" "" {T0}
1742 "Significance, torque setpoint representation (fine)" "Significance, force setpoint representation (fine)" {T0}
1743 "Significance, velocity representation" "" {T0}
1744 "Weighting, velocity representation, external" "" {T0}
1745 "Weighting following error representation DSC" "" {T0}
1750 "Power module temperature" "" {T0}
1751 "Electronics temperature" "" {T0}
1752 "Speed, internal fan" "" {T0}
1753 "Speed, external fan" "" {T0}
1754 "Unformatted power module data" "" {T0}
1760 "Feedback, teach-in traversing blcok index" "" {T0}
1761 "Feedback, teach-in default block index" "" {T0}
1762 "Feedback teach-in counter" "" {T0}
1781 "Setpoint source, process data PROFIBUS" "" {T0}
1782 "Target offset PROFIBUS process data" "" {T0}
1783 "PROFIBUS parameterization data received" "" {T0}
1784 "PROFIBUS configuration data received" "" {T0}
1785 "Expanded PROFIBUS diagnostics" "" {T0}
1786 "PKW data received, PROFIBUS" "" {T0}
1787 "PKW data sent, PROFIBUS" "" {T0}
1788 "Processed data received via PROFIBUS" "" {T0}
1788b0 " " "" {T0}
1788b1 " " "" {T0}
1788b2 " " "" {T0}
1788b3 " " "" {T0}
1788b4 " " "" {T0}
1788b5 " " "" {T0}
1788b6 " " "" {T0}
1788b7 " " "" {T0}
1788b8 " " "" {T0}
1788b9 " " "" {T0}
1788b10 " " "" {T0}
1788b11 " " "" {T0}
1788b12 " " "" {T0}
1788b13 " " "" {T0}
1788b14 " " "" {T0}
1788b15 " " "" {T0}
1789 "Process data sent via PROFIBUS" "" {T0}
1789b0 " " "" {T0}
1789b1 " " "" {T0}
1789b2 " " "" {T0}
1789b3 " " "" {T0}
1789b4 " " "" {T0}
1789b5 " " "" {T0}
1789b6 " " "" {T0}
1789b7 " " "" {T0}
1789b8 " " "" {T0}
1789b9 " " "" {T0}
1789b10 " " "" {T0}
1789b11 " " "" {T0}
1789b12 " " "" {T0}
1789b13 " " "" {T0}
1789b14 " " "" {T0}
1789b15 " " "" {T0}
1790 "Meas. circ. type indirect meas. system" "" {T0}
1791 "Meas. circ. type direct meas. system" "" {T0}
1792 "Active measuring system" "" {T0}
1794 "<22>ption module (PROFIBUS): Version initial program loader" "" {T0}
1795 "Option module (PROFIBUS): Version firmware" "" {T0}
1796 "Initializer version" "" {T0}
1798 "Firmware date" "" {T0}
1799 "Firmware version" "" {T0}
1800 "Function generator control" "" {T0}
1801 "Function generator status" "" {T0}
1802 "Measuring function control" "" {T0}
1803 "Measuring function status" "" {T0}
1804 "Function generator operating mode" "" {T0}
1805 "Function generator curve shape" "" {T0}
1806 "Start-up function amplitude" "" {T0}
1807 "Start-up function offset" "" {T0}
1808 "Function generator limitation" "" {T0}
1809 "Function generator 2nd amplitude (staircase)" "" {T0}
1810 "Function generator period" "" {T0}
1811 "Function generator, pulse width (squarewave)" "" {T0}
1812 "Start-up function, bandwidth (FFT)" "" {T0}
1813 "Start-up function, ramp-up time to P1400" "" {T0}
1814 "Measuring function meas. type" "" {T0}
1815 "Measuring function meas. period (step change)" "" {T0}
1816 "Measuring function settling time" "" {T0}
1817 "Measuring function no. of averaging ops. (FFT)" "" {T0}
1820 "Signal number test socket 1" "" {T0}
1821 "Shift factor test socket 1" "" {T0}
1822 "Offset test socket 1" "" {T0}
1823 "Segment address test socket 1" "" {T0}
1824 "Offset address test socket 1" "" {T0}
1826 "Status test socket 1" "" {T0}
1830 "Signal number test socket 2" "" {T0}
1831 "Shift factor test socket 2" "" {T0}
1832 "Offset test socket 2" "" {T0}
1833 "Segment address test socket 2" "" {T0}
1834 "Offset address test socket 2" "" {T0}
1836 "Status test socket 2" "" {T0}
1842 "HOST: Control word simulation" "" {T0}
1845 "HOST: Analog input 1" "" {T0}
1846 "HOST: Analog input 2" "" {T0}
1870 "HOST: Load torque" "" {T0}
1880 "HOST: Background cycle (position controller cycles)" "" {T0}
1890 "HOST: ZK1_PO register" "" {T0}
1891 "HOST: ZK1_RES register" "" {T0}
1899 "Actual status display of the trace control" "" {T0}
1900 "Status word for the trace control" "" {T0}
1901 "Trace cycle" "" {T0}
1902 "Trace sample number" "" {T0}
1903 "Trace mode" "" {T0}
1904 "Trace trigger level Hi" "" {T0}
1905 "Trace trigger level Lo" "" {T0}
1906 "Trace edge trigger, delta value" "" {T0}
1907 "Trace trigger delay" "" {T0}
1908 "Trace trigger signal number" "" {T0}
1909 "Trace memory segment trigger signal" "" {T0}
1910 "Trace phys. trigger signal address" "" {T0}
1911 "Modular drive position of the trace trigger signal" "" {T0}
1912 "Trace signal number" "" {T0}
1914 "Trace memory segment" "" {T0}
1915 "Trace phys. signal address" "" {T0}