; GSD-Datei fuer PROFIBUS-DP Koppler/SPC 3
|
|
; Hersteller: Beckhoff Industrie Elektronik
|
|
; Eiserstr. 5
|
|
; 33415 Verl
|
|
; Tel.: 05246 936 0
|
|
; Best.-Nr.: FM3312/FM332
|
|
; Stand : 10/25/01
|
|
;
|
|
;======================================================
|
|
;
|
|
;
|
|
|
|
Tc_Vendor_TreeImage = 101
|
|
Tc_Firmware_Flashable = 1
|
|
Tc_BitmapFile = "Fm33xx.bmp"
|
|
Tc_VendorBitmapFile = "Beckhoff.bmp"
|
|
|
|
#Profibus_DP
|
|
GSD_Revision = 1 ; erweiterte GSD-Datei wird unterstuetzt (gemaess PNO-Richtlinie 14.12.95)
|
|
Vendor_Name = "BECKHOFF INDUSTRIE ELEKTRONIK" ; Herstellername
|
|
Model_Name = "FM3312" ; Bezeichnung des DP-Geraetes
|
|
Revision = "Ausgabestand B0" ; Ausgabestand des DP-Geraetes
|
|
Ident_Number = 0xBECE ; Geraetetyp des DP-Geraetes
|
|
Protocol_Ident = 0 ; Protokollkennung PROFIBUS-DP
|
|
Station_Type = 0 ; DP-Slave
|
|
FMS_supp = 0 ; FMS/DP-Mischgeraet
|
|
Hardware_Release = "A00" ; Hardware-Ausgabestand
|
|
Software_Release = "B0" ; Software-Ausgabestand
|
|
; DP-Geraet unterstuetzt die Baudraten
|
|
9.6_supp = 1 ; 9.6 kBaud
|
|
19.2_supp = 1 ; 19.2 kBaud
|
|
93.75_supp = 1 ; 93.75 kBaud
|
|
187.5_supp = 1 ; 187.5 kBaud
|
|
500_supp = 1 ; 500 kBaud
|
|
1.5M_supp = 1 ; 1.5 MBaud
|
|
3M_supp = 1 ; 3 MBaud
|
|
6M_supp = 1 ; 6 MBaud
|
|
12M_supp = 1 ; 12 MBaud
|
|
MaxTsdr_9.6 = 60
|
|
MaxTsdr_19.2 = 60
|
|
MaxTsdr_93.75 = 60
|
|
MaxTsdr_187.5 = 60
|
|
MaxTsdr_500 = 100
|
|
MaxTsdr_1.5M = 150
|
|
MaxTsdr_3M = 250
|
|
MaxTsdr_6M = 350
|
|
MaxTsdr_12M = 550
|
|
Redundancy = 0 ; keine redundante Uebertragung
|
|
Repeater_Ctrl_Sig = 0 ; Steckersignal CNTR-P nicht angeschlossen
|
|
24V_Pins = 0 ; Steckersignale M24V und P24V nicht angeschlossen
|
|
|
|
Implementation_Type = "SPC3" ; ASIC SPC3 wird verwendet
|
|
Bitmap_Device = "fm33xx" ; Bitmap fuer Normalzustand
|
|
|
|
;-------------------- Slave spezifische Werte --------------
|
|
|
|
Freeze_Mode_supp = 1 ; Freeze-Mode wird unterstueetzt
|
|
Sync_Mode_supp = 1 ; Sync-Mode wird unterstuetzt
|
|
Auto_Baud_supp = 1 ; Autom. Baudratenerkennung
|
|
Set_Slave_Add_supp = 0 ; Set_Slave_Add wird nicht unterstuetzt
|
|
Max_User_Prm_Data_Len = 31 ; 31 Byte max. User-Parameter-Daten
|
|
User_Prm_Data_Len = 31 ; 31 Byte User-Parameter-Daten
|
|
User_Prm_Data = 0x00,0x00,0x00,0x00,0x00,\
|
|
0x00,0x00,0x00,0x00,0x23,\
|
|
0x00,0x10,0x00,0x00,0x00,\
|
|
0x55,0x55,0x55,0x55,0x55,\
|
|
0x55,0x55,0x55,0x00,0x00,\
|
|
0x00,0x00,0x00,0x00,0x00,\
|
|
0x00 ; Defaultwerte fuer User-Prm-Data
|
|
Min_Slave_Intervall = 1 ;
|
|
Modular_Station = 0 ; Modulare Station
|
|
|
|
Fail_Safe = 1 ; Datentelegramm ohne Daten wird im CLEAR-Fall nicht akzeptiert
|
|
Max_Diag_Data_Len = 64 ; maximale Laenge der Diagnosedaten
|
|
Modul_Offset = 0 ; erstes Modul im Konfigurationstool
|
|
Slave_Family = 3 ; Geraete-Familie: I/O
|
|
|
|
;
|
|
;---------------------- DPV1 -------------------------
|
|
;
|
|
DPV1_Slave = 1
|
|
C1_Read_Write_supp = 1
|
|
C1_Max_Data_Len = 48
|
|
C1_Response_Timeout = 1000
|
|
C2_Read_Write_supp = 1
|
|
C2_Max_Data_Len = 48
|
|
C2_Response_Timeout = 1000
|
|
C2_Max_Count_Channels = 1
|
|
Max_Initiate_PDU_Length = 52
|
|
|
|
;-------------------- Module -------------------------
|
|
Module = "Channel 1" 0x50
|
|
EndModule
|
|
Module = "Channel 2" 0x50
|
|
EndModule
|
|
Module = "Channel 3" 0x50
|
|
EndModule
|
|
Module = "Channel 4" 0x50
|
|
EndModule
|
|
Module = "Channel 5" 0x50
|
|
EndModule
|
|
Module = "Channel 6" 0x50
|
|
EndModule
|
|
Module = "Channel 7" 0x50
|
|
EndModule
|
|
Module = "Channel 8" 0x50
|
|
EndModule
|
|
Module = "Channel 9" 0x50
|
|
EndModule
|
|
Module = "Channel 10" 0x50
|
|
EndModule
|
|
Module = "Channel 11" 0x50
|
|
EndModule
|
|
Module = "Channel 12" 0x50
|
|
EndModule
|
|
Module = "Channel State Open Circuit " 0x13
|
|
EndModule
|
|
Module = "Channel State Back Voltage " 0x13
|
|
EndModule
|
|
Module = "Measure Control " 0x20
|
|
EndModule
|
|
Module = "Measure State " 0x10
|
|
EndModule
|
|
|
|
; erweiterte Beschreibung der User-Parameter
|
|
|
|
PrmText = 2
|
|
Text(0) = "INTEL"
|
|
Text(1) = "MOTOROLA"
|
|
EndPrmText
|
|
|
|
PrmText = 4
|
|
Text(0) = "leave data excahnge"
|
|
Text(1) = "DP-inputs will be 0"
|
|
Text(2) = "DP-inputs will be unchanged"
|
|
EndPrmText
|
|
|
|
PrmText = 10
|
|
Text(0) = "Channel connected"
|
|
Text(1) = "Channel not connected"
|
|
EndPrmText
|
|
|
|
ExtUserPrmData = 2 "Data Format"
|
|
Bit(3) 0 0-1
|
|
Prm_Text_Ref = 2
|
|
EndExtUserPrmData
|
|
|
|
ExtUserPrmData = 3 "Reaction on PROFIBUS-fault"
|
|
BitArea(0-1) 0 0-2
|
|
Prm_Text_Ref = 3
|
|
EndExtUserPrmData
|
|
|
|
ExtUserPrmData = 4 "Reaction on I/O-fault"
|
|
BitArea(2-3) 0 0-2
|
|
Prm_Text_Ref = 4
|
|
EndExtUserPrmData
|
|
|
|
ExtUserPrmData = 10 "Connection Channel 1"
|
|
BitArea(0-1) 0 0-1
|
|
Prm_Text_Ref = 10
|
|
EndExtUserPrmData
|
|
|
|
ExtUserPrmData = 11 "Connection Channel 2"
|
|
BitArea(2-3) 0 0-1
|
|
Prm_Text_Ref = 10
|
|
EndExtUserPrmData
|
|
|
|
ExtUserPrmData = 12 "Connection Channel 3"
|
|
BitArea(4-5) 0 0-1
|
|
Prm_Text_Ref = 10
|
|
EndExtUserPrmData
|
|
|
|
ExtUserPrmData = 13 "Connection Channel 4"
|
|
BitArea(6-7) 0 0-1
|
|
Prm_Text_Ref = 10
|
|
EndExtUserPrmData
|
|
|
|
ExtUserPrmData = 14 "Connection Channel 5"
|
|
BitArea(0-1) 0 0-1
|
|
Prm_Text_Ref = 10
|
|
EndExtUserPrmData
|
|
|
|
ExtUserPrmData = 15 "Connection Channel 6"
|
|
BitArea(2-3) 0 0-1
|
|
Prm_Text_Ref = 10
|
|
EndExtUserPrmData
|
|
|
|
ExtUserPrmData = 16 "Connection Channel 7"
|
|
BitArea(4-5) 0 0-1
|
|
Prm_Text_Ref = 10
|
|
EndExtUserPrmData
|
|
|
|
ExtUserPrmData = 17 "Connection Channel 8"
|
|
BitArea(6-7) 0 0-1
|
|
Prm_Text_Ref = 10
|
|
EndExtUserPrmData
|
|
|
|
ExtUserPrmData = 18 "Connection Channel 9"
|
|
BitArea(0-1) 0 0-1
|
|
Prm_Text_Ref = 10
|
|
EndExtUserPrmData
|
|
|
|
ExtUserPrmData = 19 "Connection Channel 10"
|
|
BitArea(2-3) 0 0-1
|
|
Prm_Text_Ref = 10
|
|
EndExtUserPrmData
|
|
|
|
ExtUserPrmData = 20 "Connection Channel 11"
|
|
BitArea(4-5) 0 0-1
|
|
Prm_Text_Ref = 10
|
|
EndExtUserPrmData
|
|
|
|
ExtUserPrmData = 21 "Connection Channel 12"
|
|
BitArea(6-7) 0 0-1
|
|
Prm_Text_Ref = 10
|
|
EndExtUserPrmData
|
|
|
|
Ext_User_Prm_Data_Const(0) = 0x00,0x00,0x00,0x00,0x00 ; 5 Bytes reservierte UserPrmData
|
|
Ext_User_Prm_Data_Const(5) = 0x00 ; Bits 1-7 werden mit 0 vorbelegt
|
|
Ext_User_Prm_Data_Const(6) = 0x00,0x00,0x00 ; 3 Bytes reservierte UserPrmData
|
|
Ext_User_Prm_Data_Const(9) = 0x23 ; Bits 0,1,5 werden mit 1, Bits 2,4,6,7 mit 0 vorbelegt
|
|
Ext_User_Prm_Data_Ref(9) = 2 ; Bit 3: Referenznummer 2
|
|
Ext_User_Prm_Data_Const(10) = 0x00 ; Bits 4-7 werden mit 0 vorbelegt
|
|
Ext_User_Prm_Data_Ref(10) = 4 ; Bit 2-3: Referenznummer 4
|
|
Ext_User_Prm_Data_Const(11) = 0x40,0x00,0x00,0x00 ; 4 Bytes reservierte UserPrmData
|
|
Ext_User_Prm_Data_Ref(15) = 10 ; Referenznummer 10
|
|
Ext_User_Prm_Data_Ref(15) = 11 ; Referenznummer 11
|
|
Ext_User_Prm_Data_Ref(15) = 12 ; Referenznummer 12
|
|
Ext_User_Prm_Data_Ref(15) = 13 ; Referenznummer 13
|
|
Ext_User_Prm_Data_Ref(16) = 14 ; Referenznummer 14
|
|
Ext_User_Prm_Data_Ref(16) = 15 ; Referenznummer 15
|
|
Ext_User_Prm_Data_Ref(16) = 16 ; Referenznummer 16
|
|
Ext_User_Prm_Data_Ref(16) = 17 ; Referenznummer 17
|
|
Ext_User_Prm_Data_Ref(17) = 18 ; Referenznummer 18
|
|
Ext_User_Prm_Data_Ref(17) = 19 ; Referenznummer 19
|
|
Ext_User_Prm_Data_Ref(17) = 20 ; Referenznummer 20
|
|
Ext_User_Prm_Data_Ref(17) = 21 ; Referenznummer 21
|
|
Ext_User_Prm_Data_Const(18) = 0x55,0x55,0x55,0x55,0x55 ; 5 Bytes reservierte UserPrmData
|
|
Ext_User_Prm_Data_Const(23) = 0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00 ; 8 Bytes reservierte UserPrmData
|
|
|