; GSD-file for PROFIBUS-DP Coupler/SPC3
|
|
; Manufacturer: Beckhoff Automation GmbH
|
|
; Eiserstr. 5
|
|
; 33415 Verl (Germany)
|
|
; Tel.: +49(0)5246/963-0
|
|
; stock-nr.: IP10xx-B310
|
|
; state: 02.06.06
|
|
;
|
|
;
|
|
;----------------------- TwinCAT ----------------------
|
|
;
|
|
Tc_KBus_supp = 1 ; Bus-Coupler
|
|
Tc_Plc_supp = 0 ; Bus-Controller
|
|
Tc_Fbb_supp = 1 ; Fieldbus Box
|
|
Tc_Firmware_Flashable = 1 ;
|
|
Tc_Valid_Term(0) = 1677722600 ; 0x64000000 + 1000
|
|
Tc_Valid_Term(1) = 1677722601 ; 0x64000000 + 1001
|
|
Tc_Valid_Term(2) = 1677722602 ; 0x64000000 + 1002
|
|
Tc_Valid_Term(3) = 1677722610 ; 0x64000000 + 1010
|
|
Tc_Valid_Term(4) = 1677722611 ; 0x64000000 + 1011
|
|
Tc_Valid_Term(5) = 1677722612 ; 0x64000000 + 1012
|
|
Tc_Valid_Term(6) = 1677722620 ; 0x64000000 + 1020
|
|
Tc_Valid_Term(7) = 1677722621 ; 0x64000000 + 1021
|
|
Tc_Valid_Term(8) = 1677722622 ; 0x64000000 + 1022
|
|
Tc_Comment = "Digital Input Compact Box"
|
|
Tc_BitmapFile = "Ip.bmp"
|
|
Tc_VendorBitmapFile = "Beckhoff.bmp"
|
|
;
|
|
;------------------------- DP -------------------------
|
|
;
|
|
#Profibus_DP
|
|
;
|
|
;------------------ PrmText-Definitionen --------------
|
|
;
|
|
PrmText = 1
|
|
Text(0) = "is not active"
|
|
Text(1) = "is active"
|
|
EndPrmText
|
|
|
|
;
|
|
;------------- ExtUserPrmData-Definitionen --------------
|
|
;
|
|
ExtUserPrmData = 86 "Fast FreeRun-Mode"
|
|
Bit(4) 0 0-1
|
|
Prm_Text_Ref = 1
|
|
EndExtUserPrmData
|
|
|
|
;
|
|
;---------------------- DP-General ---------------------
|
|
;
|
|
GSD_Revision = 2
|
|
Vendor_Name = "BECKHOFF"
|
|
Model_Name = "IP10xx-B3xx"
|
|
Revision = "Revision 3.2"
|
|
Ident_Number = 0x0518
|
|
Protocol_Ident = 0
|
|
Station_Type = 0
|
|
FMS_supp = 0
|
|
Hardware_Release = "08"
|
|
Software_Release = "B3"
|
|
|
|
9.6_supp = 1
|
|
19.2_supp = 1
|
|
93.75_supp = 1
|
|
187.5_supp = 1
|
|
500_supp = 1
|
|
1.5M_supp = 1
|
|
3M_supp = 1
|
|
6M_supp = 1
|
|
12M_supp = 1
|
|
MaxTsdr_9.6 = 60
|
|
MaxTsdr_19.2 = 60
|
|
MaxTsdr_93.75 = 60
|
|
MaxTsdr_187.5 = 60
|
|
MaxTsdr_500 = 100
|
|
MaxTsdr_1.5M = 150
|
|
MaxTsdr_3M = 250
|
|
MaxTsdr_6M = 350
|
|
MaxTsdr_12M = 550
|
|
Redundancy = 0
|
|
Repeater_Ctrl_Sig = 0
|
|
24V_Pins = 0
|
|
|
|
Implementation_Type = "SPC3"
|
|
Bitmap_Device = "Ip"
|
|
;
|
|
;-------------------- DP-Slave -----------------------
|
|
;
|
|
Freeze_Mode_supp = 1
|
|
Sync_Mode_supp = 1
|
|
Auto_Baud_supp = 1
|
|
Set_Slave_Add_supp = 0
|
|
Min_Slave_Intervall = 1
|
|
Modular_Station = 0
|
|
|
|
Fail_Safe = 1
|
|
Max_Diag_Data_Len = 64
|
|
Slave_Family = 3
|
|
;
|
|
;---------------------- DPV1 -------------------------
|
|
;
|
|
;
|
|
;------------------- UserPrmData ---------------------
|
|
;
|
|
Max_User_Prm_Data_Len = 15
|
|
|
|
Ext_User_Prm_Data_Const(0) = 0x00
|
|
Ext_User_Prm_Data_Const(1) = 0x00
|
|
Ext_User_Prm_Data_Const(2) = 0x08
|
|
Ext_User_Prm_Data_Const(3) = 0x00
|
|
Ext_User_Prm_Data_Const(4) = 0x00
|
|
Ext_User_Prm_Data_Const(5) = 0x00
|
|
Ext_User_Prm_Data_Const(6) = 0x00
|
|
Ext_User_Prm_Data_Const(7) = 0x40
|
|
Ext_User_Prm_Data_Const(8) = 0x00
|
|
Ext_User_Prm_Data_Const(9) = 0x63
|
|
Ext_User_Prm_Data_Ref(9) = 86
|
|
Ext_User_Prm_Data_Const(10) = 0x00
|
|
Ext_User_Prm_Data_Const(11) = 0x40
|
|
Ext_User_Prm_Data_Const(12) = 0x00
|
|
Ext_User_Prm_Data_Const(13) = 0x00,0x00
|
|
;
|
|
;-------------------- Modules ------------------------
|
|
;
|
|
Module = "8 Bit digital inputs" 0x10
|
|
153
|
|